W DOC AIRBUS | AMM A320F

Installation of the Seal at Pylon Rib 5


TASK 54-52-11-400-003-A
Installation of the Seal at Pylon Rib 5


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 410
ZONE: 420
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.05JBC9)
Contact Adhesive-Rubber & Plastic Bonding Neoprene base -
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
410
ENG 1 PYLON BOX AND FORWARD FAIRING
420
ENG 2 PYLON BOX AND FORWARD FAIRING
413AL, 423AL
414AR, 424AR
413AR, 423AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 54-52-11-400-002-A
Installation of the Access Panels
TASK 54-52-11-400-002-B
Installation of the Access Panels
TASK 78-30-00-040-013-A
Deactivation of the Thrust Reverser System for Flight
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-440-013-A
Activation of the Thrust Reverser System for Flight
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
3. Job Set-up
Subtask 54-52-11-941-054-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Put the WARNING NOTICE(S) in position to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
   (3) On overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put the WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
Subtask 54-52-11-860-052-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position:
     (a) At zone 410 for the left pylon,
     (b) At zone 420 for the right pylon.
Subtask 54-52-11-040-056-A ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser
WARNING: MAKE THE THRUST REVERSER UNSERVICEABLE. IF THE THRUST REVERSER IS NOT MADE UNSERVICEABLE, IT CAN OPERATE ACCIDENTALLY BECAUSE THE BLOCKER DOOR HOLD-OPEN ROD DOES NOT RESIST THE ACTUATOR HYDRAULIC PRESSURE. THIS CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041).
Subtask 54-52-11-040-056-B ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser
WARNING: MAKE THE THRUST REVERSER UNSERVICEABLE. IF THE THRUST REVERSER IS NOT MADE UNSERVICEABLE, IT CAN OPERATE ACCIDENTALLY BECAUSE THE BLOCKER DOOR HOLD-OPEN ROD DOES NOT RESIST THE ACTUATOR HYDRAULIC PRESSURE. THIS CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-013).
Subtask 54-52-11-110-051-A ** ON A/C NOT FOR ALL
D. Preparation for Installation
   (1) Use the Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the flange and the front panel that touches the seal.
   (2) Use the Textile-Lint free Cotton - (Material No.14SBA1) to dry the area.
4. Procedure
Subtask 54-52-11-420-053-A ** ON A/C NOT FOR ALL
A. Installation of the Seal
   (1) Apply Contact Adhesive-Rubber & Plastic Bonding Neoprene base - (Material No.05JBC9) to the flange.
   (2) Engage the new seal (1) on the edge of the flange.
5. Close-up
Subtask 54-52-11-410-055-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Close access panels 413AL, 414AR, 423AL and 424AR
(Ref. AMM TASK 54-52-11-400-002).
Subtask 54-52-11-410-055-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Close access panels 413AL, 413AR, 423AL and 423AR
(Ref. AMM TASK 54-52-11-400-002).
Subtask 54-52-11-440-051-A ** ON A/C NOT FOR ALL
B. Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
Subtask 54-52-11-440-051-B ** ON A/C NOT FOR ALL
B. Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-013).
Subtask 54-52-11-860-053-A ** ON A/C NOT FOR ALL
C. Aircraft System Configuration
   (1) Remove all the fixtures, tools, test and support equipment used during this procedure.
[Rev.10 from 2021] 2026.04.01 02:01:58 UTC