General Visual Inspection of Pylon, Reverser Fittings
TASK 54-51-00-210-802-A
General Visual Inspection of Pylon, Reverser Fittings
Refer to the MPD TASK: 545228-01
GENERAL VISUAL INSPECTION OF PYLON, REVERSER FITTINGS.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 54-51-00-941-098-A ** ON A/C NOT FOR ALL
Subtask 54-51-00-210-053-A ** ON A/C NOT FOR ALL
Subtask 54-51-00-410-108-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:00:03 UTC
General Visual Inspection of Pylon, Reverser Fittings
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
DO NOT APPLY TEMPORARY PROTECTION SYSTEM (TPS) ON THE INSPECTION AREA. IF YOU APPLY TPS ON THE INSPECTION AREA, YOU CAN CAUSE DAMAGE TO THE AIRCRAFT.
1. Reason for the JobRefer to the MPD TASK: 545228-01
GENERAL VISUAL INSPECTION OF PYLON, REVERSER FITTINGS.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 410 | ENG 1 PYLON BOX AND FORWARD FAIRING |
| 420 | ENG 2 PYLON BOX AND FORWARD FAIRING |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 451DL, 451EL, 452DR, 452ER | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 461DL, 461EL, 462DR, 462ER | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 51-78-00-916-001-A | Application of Temporary Protection System (TPS) |
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-805-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
| TASK 78-30-06-000-801-A | Removal of the Thrust Reverser Hinge Access Panels |
| TASK 78-30-06-400-801-A | Installation of the Thrust Reverser Hinge Access Panels |
| SRM 511100 | (for corrective action) |
| SRM 512200 | (for corrective action) |
Subtask 54-51-00-941-098-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 54-51-00-040-093-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
B. Deactivation of the thrust reverser
Subtask 54-51-00-010-097-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-805). C. Removal of the Access Panels
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
(a) For left pylon in zone 410
(b) For right pylon in zone 420.
(2) Remove the thrust reverser hinge access-panels (Ref. AMM TASK 78-30-06-000-801):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451DL, 451EL, 452DR, 452ER
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461DL, 461EL, 462DR, 462ER.
Subtask 54-51-00-110-094-A ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
(a) For left pylon in zone 410
(b) For right pylon in zone 420.
(2) Remove the thrust reverser hinge access-panels (Ref. AMM TASK 78-30-06-000-801):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451DL, 451EL, 452DR, 452ER
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461DL, 461EL, 462DR, 462ER.
D. Preparation of the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If it is not sufficiently clean, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Make sure that there is no Temporary Protection System (TPS) layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If it is not sufficiently clean, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Make sure that there is no Temporary Protection System (TPS) layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
Subtask 54-51-00-210-053-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Do a general visual inspection of the reverser fittings of the pylon.
(2) Make sure that there is no:
(a) Corrosion damage:
5. Close-up(1) Do a general visual inspection of the reverser fittings of the pylon.
(2) Make sure that there is no:
(a) Corrosion damage:
- If you find corrosion damage, refer to Structural Repair Manual SRM 512200 for types of corrosion, inspection, removal and corrosion protection.
- If you find this type of damage, refer to Structural Repair Manual SRM 511100 for damage classification and related corrective action.
Subtask 54-51-00-410-108-A ** ON A/C NOT FOR ALL
A. Installation of the panels
(1) Install the thrust reverser hinge access-panels (Ref. AMM TASK 78-30-06-400-801):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451DL, 451EL, 452DR, 452ER
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461DL, 461EL, 462DR, 462ER.
Subtask 54-51-00-440-092-A ** ON A/C NOT FOR ALL (1) Install the thrust reverser hinge access-panels (Ref. AMM TASK 78-30-06-400-801):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451DL, 451EL, 452DR, 452ER
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461DL, 461EL, 462DR, 462ER.
B. Reactivation of the Thrust Reverser
(1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 54-51-00-942-061-A ** ON A/C NOT FOR ALL (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-805).
C. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Reverser Fittings of the Pylon