W DOC AIRBUS | AMM A320F

Installation of the Proximity Switches


TASK 52-71-12-400-002-A
Installation of the Proximity Switches


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 825
ZONE: 826
FIN: 30WV
FIN: 32WV
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
CAP - BLANKING
98D52308001000
1
GAUGE PROX SENSOR
98D52308002000
1
CURVED SHIM
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.06AAA1)
Polysulfide Sealant_General Purpose Brushable -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
825
FORWARD CARGO COMPARTMENT DOOR
826
AFT CARGO COMPARTMENT DOOR
825AR, 826AR
826BR, 826CR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-31-14-000-801-A
Removal of the FWD Cargo-Compartment Door Access-Panel
TASK 52-31-14-400-801-A
Installation of the FWD Cargo-Compartment Door Access-Panel
TASK 52-32-14-000-801-A
Removal of the Aft Cargo-Compartment-Door Access-Panels
TASK 52-32-14-400-801-A
Installation of the Aft Cargo-Compartment-Door Access-Panels
TASK 52-71-00-820-003-A
Adjustment of the Proximity Switches of the Cargo-Compartment Door Threshold
F Proximity Switches 30WV and 32WV ** ON A/C NOT FOR ALL
F Proximity Switches 30WV and 32WV ** ON A/C NOT FOR ALL
F Proximity Switches 30WV and 32WV ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 52-71-12-860-053-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Make sure that the applicable cargo door is open (Ref. AMM TASK 52-30-00-860-001).
   (2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position for the applicable cargo door.
   (3) Make sure that access panel(s) 825AR and/or 826AR are removed
(Ref. AMM TASK 52-31-14-000-801) and/or (Ref. AMM TASK 52-32-14-000-801).
Subtask 52-71-12-860-053-B ** ON A/C NOT FOR ALL
A. Get Access
   (1) Make sure that the the applicable cargo door is open (Ref. AMM TASK 52-30-00-860-001).
   (2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position for the applicable cargo door.
   (3) Make sure that access panel(s) 825AR and/or 826AR, 826BR and 826CR are removed
(Ref. AMM TASK 52-31-14-000-801) and/or (Ref. AMM TASK 52-32-14-000-801).
Subtask 52-71-12-865-054-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
122VUDOORS/CARGO1MJT12
4. Procedure
Subtask 52-71-12-910-050-A
A. Preparation for the Installation
   (1) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Make sure that all the electrical connections are clean and in the correct condition.
   (4) Apply Polysulfide Sealant_General Purpose Brushable - (Material No.06AAA1) on the areas between the proximity sensor (23) and the fuselage fitting (24).
   (5) Apply Polysulfide Sealant_General Purpose Brushable - (Material No.06AAA1) on the area between the target (31) and the target lever (32).
Subtask 52-71-12-420-051-A ** ON A/C NOT FOR ALL
B. Installation of the Proximity Switch
   (1) Install the proximity sensor (23) as follows:
     (a) Put the proximity sensor (23) in position on the fuselage fitting (24).
     (b) Install the screws (22), the washers (25) and the nuts (26) and tighten them.
     (c) Remove the blanking caps from the electrical connector (21) and the receptacle of the proximity sensor (23).
     (d) Install the electrical connector (21) on the proximity sensor (23).
   (2) Install the target (31) as follows:
     (a) Put the target (31) in position on the target lever (32).
     (b) Install the screws (30), the washers (33) and the nuts (34) and tighten them.
Subtask 52-71-12-420-051-B ** ON A/C NOT FOR ALL
B. Installation of the Proximity Switch
   (1) Install the proximity sensor (23) as follows:
     (a) Make sure that the clip nuts (26) are clean and in the correct condition.
     (b) If necessary, replace the defective clip nuts (26).
     (c) Put the proximity sensor (23) in position on the fuselage fitting (24).
     (d) Install the washers (25) and the screws (22).
     (e) Tighten the screws (22).
     (f) Remove the CAP - BLANKING from the electrical connector (21) and the receptacle of the proximity sensor (23).
     (g) Connect the electrical connector (21) on the proximity sensor (23).
   (2) Install the target (31) as follows:
     (a) Put the target (31) in position on the target lever (32).
     (b) Install the screws (30), the washers (33) and the nuts (34).
     (c) Tighten the nuts (34).
Subtask 52-71-12-820-051-A
C. Rigging of the Proximity Switch
CAUTION: BEFORE YOU INSTALL/REMOVE THE GSE-TOOL, READ THE INSTRUCTIONS IN THE APPLICABLE GSE INSTRUCTION MANUAL. WHILE YOU OPERATE THIS TOOL, CAREFULLY OBEY THEM. IF YOU DO NOT OBEY THE INSTRUCTIONS, DAMAGE TO EQUIPMENT CAN OCCUR.
   (1) Close the applicable cargo compartment door (Ref. AMM TASK 52-30-00-860-002).
   (2) Use the 98D52308002000 CURVED SHIM to measure clearance J1 between the target (31) and the related proximity switch (23).
NOTE: Clearance J1 must be between 1.0 mm (0.0394 in.) and 1.8 mm (0.0709 in.).
   (3) If clearance J1 is out of tolerance, do the rigging of the proximity switch (23) with the 98D52308002000 CURVED SHIM and the 98D52308001000 GAUGE PROX SENSOR (Ref. AMM TASK 52-71-00-820-003).
Subtask 52-71-12-865-055-A
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
122VUDOORS/CARGO1MJT12
Subtask 52-71-12-720-051-A
E. Operational Test
   (1) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
   (2) Do this test to make sure that the proximity switch operates correctly.
ACTION
RESULT
1.On the FWD and/or Aft cargo door(s):
  • Pull the locking handle away from the cargo door.
On the lower display unit of the ECAM system:
  • The symbol of the applicable cargo door and the CARGO message are shown in amber.
  • Push the locking handle into the recess of the handle flap.
  • The symbol for the applicable cargo door changes to green.
  • The related CARGO message goes off.
   (3) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (4) If necessary, adjust the applicable proximity switch (Ref. AMM TASK 52-71-00-820-003).
5. Close-up
Subtask 52-71-12-410-052-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install access panel(s) 825AR and/or 826AR on the applicable cargo door
(Ref. AMM TASK 52-31-14-400-801) and/or (Ref. AMM TASK 52-32-14-400-801).
   (3) Make sure that the applicable cargo door is correctly closed (Ref. AMM TASK 52-30-00-860-002).
   (4) Remove the access platform(s).
Subtask 52-71-12-410-052-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install access panel(s) 825AR and/or 826AR, 826BR and 826CR on the applicable cargo door
(Ref. AMM TASK 52-31-14-400-801) and/or (Ref. AMM TASK 52-32-14-400-801).
   (3) Make sure that the applicable cargo door is correctly closed (Ref. AMM TASK 52-30-00-860-002).
   (4) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.01 12:31:16 UTC