W DOC AIRBUS | AMM A320F

Detailed Inspection of Aft Emergency Exits, Internal Structure, LH/RH


TASK 52-22-11-200-002-A
Detailed Inspection of Aft Emergency Exits, Internal Structure, LH/RH


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 835
ZONE: 845
1. Reason for the Job
Refer to the MPD TASK: 522205-01
DETAILED INSPECTION OF AFT EMERGENCY EXITS, INTERNAL STRUCTURE, LH/RH
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
SCRAPER - PLASTIC
No specific
1
SCRAPER - WOODEN
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.12ABB1)
Corrosion Preventive Compound-Water Displacing Hard Film -
(Material No.12ABC1)
Corrosion Preventive Compound_Water Displacing Soft Film -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
835
MID PASSENGER/CREW DOOR
845
MID PASSENGER/CREW DOOR
835, 845
834, 844
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 25-23-47-000-013-A
Removal of the Door Linings of the RH FWD Emergency Exit Door at zone 251 or RH AFT at zone 252 or LH AFT at zone 232.
TASK 25-23-47-000-802-A
Removal of the Door Linings of the Emergency Exit, zones 251/252
TASK 25-23-47-400-013-A
Installation of the Door Linings of the RH FWD Emergency Exit Door at zone 251, or RH AFT at zone 252, or LH AFT at zone 232.
TASK 25-23-47-400-802-A
Installation of the Door Linings of the Emergency Exit, zones 251/252
TASK 51-75-12-300-001-A
Repair of Major Paint Damage on Light Alloy and Composite Material
TASK 51-78-00-916-001-A
Application of Temporary Protection System (TPS)
TASK 52-22-00-010-001-A
Opening of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-410-001-A
Closing of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-860-003-A
Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder
TASK 52-22-00-860-004-A
Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder
SRM 511100
SRM 512200
F Emergency Exit Doors (Example) ** ON A/C NOT FOR ALL
F Emergency Exit Doors (Example) ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 52-22-11-010-054-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Open emergency exit door 834 or 844 (Ref. AMM TASK 52-22-00-010-001).
   (2) Obey the special precautions on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-003).
   (3) Remove the door lining from the applicable emergency exit door (Ref. AMM TASK 25-23-47-000-013)
   (4) Carefully disconnect the Velcro tape and remove the insulation mats from the applicable emergency-exit door structure.
Subtask 52-22-11-010-054-B ** ON A/C NOT FOR ALL
A. Get Access
   (1) Open emergency exit door 835 or 845 (Ref. AMM TASK 52-22-00-010-001).
   (2) Obey the special precautions on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-003).
   (3) Remove the door lining from the applicable emergency exit door (Ref. AMM TASK 25-23-47-000-802).
   (4) Carefully disconnect the Velcro tape and remove the insulation mats from the applicable emergency-exit door structure.
Subtask 52-22-11-615-051-A ** ON A/C NOT FOR ALL
B. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
   (3) If there is a TPS layer and if it does not let you do a satisfactory inspection, remove the TPS layer (Ref. AMM TASK 51-78-00-916-001).
4. Procedure
Subtask 52-22-11-220-052-A ** ON A/C NOT FOR ALL
A. Inspection
   (1) Do a detailed inspection of the internal structure of the left and right aft emergency-exit-doors for damage or discontinuities.
   (2) Make sure that there is no:
     (a) Corrosion:
If you find corrosion, refer to the Structural Repair Manual SRM 512200 for the corrosion types, inspection, removal and subsequent corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual SRM 511100 for the damages types, classification and corrective action.
Subtask 52-22-11-210-051-A ** ON A/C NOT FOR ALL
B. General Inspection of the Aft Emergency-Exit-Doors
   (1) Examine the drain holes at the bottom of the aft emergency-exit-door structure. Make sure that they are not blocked.
   (2) Examine all the rivets of the aft emergency-exit-door structure:
     (a) If a rivet is missing, install a new rivet with the correct sealant.
     (b) If you find damaged or loose rivets, replace them.
   (3) Examine the sealant of all the structure components for the correct condition. If necessary, remove the damaged sealant with the SCRAPER - WOODEN or the SCRAPER - PLASTIC and apply new sealant.
   (4) Make sure that all the attachment screws and bolts of the aft emergency-exit-door structure are correctly tightened.
   (5) Make sure that the paint is in the correct condition (Ref. AMM TASK 51-75-12-300-001).
Subtask 52-22-11-916-050-A ** ON A/C NOT FOR ALL
C. Check and Application of the TPS Layer
   (1) If you removed the TPS at the "Preparation of the Inspection Area", apply a new layer of Corrosion Preventive Compound_Water Displacing Soft Film - (Material No.12ABC1) or Corrosion Preventive Compound-Water Displacing Hard Film - (Material No.12ABB1) (Ref. AMM TASK 51-78-00-916-001).
   (2) If you did not remove the TPS at the "Preparation of the Inspection Area", do a check of the condition and integrity of the TPS layer (Ref. AMM TASK 51-78-00-916-001).
   (3) If the TPS layer has local damage, remove the damaged TPS layer and apply a new layer of Corrosion Preventive Compound_Water Displacing Soft Film - (Material No.12ABC1) or Corrosion Preventive Compound-Water Displacing Hard Film - (Material No.12ABB1) (Ref. AMM TASK 51-78-00-916-001).
5. Close-up
Subtask 52-22-11-410-054-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Put the insulation mats on the applicable emergency-exit door structure and attach them with Velcro tape.
   (3) Install the door lining on the applicable emergency exit door (Ref. AMM TASK 25-23-47-400-013)
   (4) Obey the special precautions on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-004).
   (5) Close emergency exit door 834 or 844 (Ref. AMM TASK 52-22-00-410-001).
Subtask 52-22-11-410-054-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Put the insulation mats on the applicable emergency-exit door structure and attach them with Velcro tape.
   (3) Install the door lining on the applicable emergency exit door (Ref. AMM TASK 25-23-47-400-802).
   (4) Obey the special precautions on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-004).
   (5) Close emergency exit door 835 or 845 (Ref. AMM TASK 52-22-00-410-001).
[Rev.10 from 2021] 2026.04.01 01:39:11 UTC