Remove and Discard Igniter Plug(s) (APS 3200)
TASK 49-41-41-920-001-A
Remove and Discard Igniter Plug(s) (APS 3200)
Refer to the MPD TASK: 494000-A1
REMOVE AND DISCARD IGNITER PLUGS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 49-41-41-860-063-A ** ON A/C NOT FOR ALL
Subtask 49-41-41-960-051-A ** ON A/C NOT FOR ALL
Subtask 49-41-41-410-056-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:30:11 UTC
Remove and Discard Igniter Plug(s) (APS 3200)
WARNING:
DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
ZONE: 316
1. Reason for the JobRefer to the MPD TASK: 494000-A1
REMOVE AND DISCARD IGNITER PLUGS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 316 | TAIL CONE APU AND ACCESSORY COMPARTMENT |
| 315AL, 316AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 49-41-41-000-003-A | Removal of the Igniter Plug(s) (APS 3200) |
| TASK 49-41-41-400-002-A | Installation of the Igniter Plug(s) (APS 3200) |
| TASK 52-41-00-010-001-A | Open the APU Doors for Access |
| TASK 52-41-00-410-001-A | Close the APU Doors after Access |
Subtask 49-41-41-860-063-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(2) On the panel 25VU, make sure that the APU MASTER SW pushbutton switch is off.
(3) Put a WARNING NOTICE(S) in the cockpit to tell persons not to start the APU.
(4) Make sure that the hydraulic systems are depressurized
(Ref. AMM TASK 29-00-00-864-001).
Subtask 49-41-41-865-065-A ** ON A/C NOT FOR ALL (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(2) On the panel 25VU, make sure that the APU MASTER SW pushbutton switch is off.
(3) Put a WARNING NOTICE(S) in the cockpit to tell persons not to start the APU.
(4) Make sure that the hydraulic systems are depressurized
(Ref. AMM TASK 29-00-00-864-001).
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 49-41-41-010-058-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the APU access doors 315AL and 316AR.
(2) Open the APU access doors 315AL 316AR (Ref. AMM TASK 52-41-00-010-001).
(3) Make sure that the LIGHT SW 11LJ is set to the ON position.
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the APU access doors 315AL and 316AR.
(2) Open the APU access doors 315AL 316AR (Ref. AMM TASK 52-41-00-010-001).
(3) Make sure that the LIGHT SW 11LJ is set to the ON position.
Subtask 49-41-41-960-051-A ** ON A/C NOT FOR ALL
A. Remove and Discard Igniter Plug(s) (APS 3200)
(1) Remove the igniter plug(s) (Ref. AMM TASK 49-41-41-000-003).
(2) Discard the igniter plugs.
(3) Install the new igniter plug(s) (Ref. AMM TASK 49-41-41-400-002).
5. Close-up(1) Remove the igniter plug(s) (Ref. AMM TASK 49-41-41-000-003).
(2) Discard the igniter plugs.
(3) Install the new igniter plug(s) (Ref. AMM TASK 49-41-41-400-002).
Subtask 49-41-41-410-056-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Make sure that the light SW 11LJ is set to the OFF position.
(3) Close the APU access doors 315AL 316AR (Ref. AMM TASK 52-41-00-410-001).
(4) Remove the access platform(s).
Subtask 49-41-41-865-068-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Make sure that the light SW 11LJ is set to the OFF position.
(3) Close the APU access doors 315AL 316AR (Ref. AMM TASK 52-41-00-410-001).
(4) Remove the access platform(s).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 49-41-41-860-066-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
C. Aircraft Maintenance Configuration
(1) Put the related hydraulic system in the pressurized configuration (Ref. AMM TASK 29-00-00-864-001).
(2) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(3) Remove the WARNING NOTICE(S).
(1) Put the related hydraulic system in the pressurized configuration (Ref. AMM TASK 29-00-00-864-001).
(2) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(3) Remove the WARNING NOTICE(S).