Operational Test of the Overheat Detection System


TASK 36-22-00-710-802-A
Operational Test of the Overheat Detection System


1. Reason for the Job
To do a continuity test of the overheat detection.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 36-11-00-740-802-A
BITE Test of the Engine Bleed Air System (EBAS) (System Test)
3. Job Set-up
Subtask 36-22-00-861-056-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 36-22-00-941-056-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) Make sure that engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (2) On ENG panel 115VU, put a WARNING NOTICE(S) to tell persons not to start engine 1(2).
   (3) On the ENG section of the panel 50VU:
  • Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
  • Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
4. Procedure
Subtask 36-22-00-710-052-A ** ON A/C NOT FOR ALL
A. Operational Test of the Overheat Detection System
   (1) Do the BITE Test of the EBAS with printing of the TEST RESULT page. (Ref. AMM TASK 36-11-00-740-802)
   (2) Make sure that the TEST RESULT pages do not show these maintenance indications:
ATA
MESSAGE
CLASS FAULT
362216
CHECK R WING LOOP A
2
362216
CHECK R WING LOOP B
2
362216
CHECK L WING LOOP A
2
362216
CHECK L WING LOOP B
2
362215
CHECK ENG 1 PYLON LOOP
2
362215
CHECK ENG 2 PYLON LOOP
2
362217
CHECK: APU LOOP OR
BMC IDENT CKT
2
361134
BMC1
2
361134
BMC2
2
361134
BMC1
3
361134
BMC2
3
5. Close-up
Subtask 36-22-00-942-052-A ** ON A/C NOT FOR ALL
A. Remove the WARNING NOTICE(S).
Subtask 36-22-00-862-056-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).