Functional Test of the Bleed-Pressure-Regulator Valve Control-Solenoid


TASK 36-11-55-720-001-A
Functional Test of the Bleed-Pressure-Regulator Valve Control-Solenoid


FIN: 10HA1 ** ON A/C NOT FOR ALL
FIN: 10HA2 ** ON A/C NOT FOR ALL
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [10HA1] (SOLENOID-BLEED PRESS REG V CTL, ENG 1)
413DT
413CL, 413DL, 414CR
FOR [10HA2] (SOLENOID-BLEED PRESS REG V CTL, ENG 2)
423CL, 423DL, 424CR
423DT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 36-11-55-861-051-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-55-941-053-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (2) On the AIR COND panel 30VU:
  • make sure that the ENG 1(2) BLEED pushbutton switch is released (the OFF legend is on),
  • make sure that the APU BLEED pushbutton switch is released (the ON legend is off),
  • put a WARNING NOTICE(S) to tell persons not to operate the pneumatic system.
   (3) On the ENG panel 115VU:
  • put a WARNING NOTICE(S) to tell persons not to start the engine 1(2).
   (4) On the HP ground connector:
  • Put a WARNING NOTICE(S) to tell persons not to pressurize the pneumatic system.
   (5) On the ENG section of the maintenance panel 50VU:
  • make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off,
  • put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 36-11-55-865-055-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
122VUAIR BLEED/X FEED VALVE/NORM1HVZ20
Subtask 36-11-55-010-052-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the related pylon access panel.
   (2) Remove these access panels:
     (a) FOR [10HA1] (SOLENOID-BLEED PRESS REG V CTL, ENG 1)
413CL 414CR 413DL
     (b) FOR [10HA2] (SOLENOID-BLEED PRESS REG V CTL, ENG 2)
Subtask 36-11-55-010-052-B ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the related pylon access panel.
   (2) Remove the access panel:
     (a) FOR [10HA1] (SOLENOID-BLEED PRESS REG V CTL, ENG 1)
413DT
     (b) FOR [10HA2] (SOLENOID-BLEED PRESS REG V CTL, ENG 2)
423DT.
4. Procedure
Subtask 36-11-55-720-051-A ** ON A/C NOT FOR ALL
A. Functional Test of the Bleed-Pressure-Regulator Valve Control-Solenoid
   (1) On the panel 30VU:
  • push and release the ENG 1(2) BLEED pushbutton switch and, on the related engine pylon, make sure that you hear clicks on the solenoid of the bleed-pressure-regulator valve control-solenoid.
5. Close-up
Subtask 36-11-55-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install these access panels:
     (a) FOR [10HA1] (SOLENOID-BLEED PRESS REG V CTL, ENG 1)
413CL 414CR 413DL
     (b) FOR [10HA2] (SOLENOID-BLEED PRESS REG V CTL, ENG 2)
423CL 424CR 423DL.
   (3) Remove the WARNING NOTICE(S).
   (4) Remove the access platform(s).
Subtask 36-11-55-410-051-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panel:
     (a) FOR [10HA1] (SOLENOID-BLEED PRESS REG V CTL, ENG 1)
413DT
     (b) FOR [10HA2] (SOLENOID-BLEED PRESS REG V CTL, ENG 2)
423DT.
   (3) Remove the WARNING NOTICE(S).
   (4) Remove the access platform(s).
Subtask 36-11-55-862-051-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).