Removal of the Oxygen Distribution Manifold
TASK 35-12-81-000-801-A
Removal of the Oxygen Distribution Manifold
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 35-12-81-941-050-A
[Rev.10 from 2021]
2026.04.01 01:04:20 UTC
Removal of the Oxygen Distribution Manifold
WARNING:
KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING:
CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.
CAUTION:
BE VERY CAREFUL WHEN YOU DO WORK ON OR NEAR THE AIR-CONDITIONING DUCTS. THE DUCTS ARE MADE OF THIN MATERIAL AND YOU CAN EASILY BREAK THEM.
ZONE: 125
FIN: 5753HM ** ON A/C NOT FOR ALL
FIN: 5753HM1 ** ON A/C NOT FOR ALL
FIN: 5753HM2 ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 5753HM ** ON A/C NOT FOR ALL
FIN: 5753HM1 ** ON A/C NOT FOR ALL
FIN: 5753HM2 ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | BAG - VINYL |
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| FOR [5753HM1] (MANIFOLD DISTRIBUTION) | ||
| No specific | AR | BAG - VINYL |
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN |
| FOR [5753HM2] (MANIFOLD DISTRIBUTION) | ||
| No specific | AR | BAG - VINYL |
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 125 | LATERAL AVIONIC COMPARTMENT |
| 812 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 35-00-00-860-001-A | Special Precautions When Working on a Gaseous Oxygen System |
| TASK 35-13-14-000-001-A | Removal of the Low-Pressure Oxygen Pressure-Switch |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| FOR [5753HM1] (MANIFOLD DISTRIBUTION) | |
| TASK 35-13-14-000-802-A | Removal of the Low-Pressure Oxygen Pressure-Switches |
| FOR [5753HM2] (MANIFOLD DISTRIBUTION) | |
| TASK 35-13-14-000-802-A | Removal of the Low-Pressure Oxygen Pressure-Switches |
Subtask 35-12-81-941-050-A
A. Safety Precautions
(2) Make sure that there is good airflow in the work area.
Subtask 35-12-81-861-050-A Subtask 35-12-81-010-050-A WARNING:
WHEN YOU DO WORK ON THE GASEOUS OXYGEN SYSTEM, MAKE SURE THAT YOU OBEY ALL THE APPLICABLE SAFETY PRECAUTIONS. IF YOU DO NOT OBEY THESE PRECAUTIONS, INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT CAN OCCUR.
(1) Obey the special precautions when you do work on the gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).(2) Make sure that there is good airflow in the work area.
C. Get Access
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at access door 812.
(2) Open access door 812 (Ref. AMM TASK 52-41-00-010-002).
Subtask 35-12-81-860-052-A ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at access door 812.
(2) Open access door 812 (Ref. AMM TASK 52-41-00-010-002).
D. Aircraft Maintenance Configuration
(1) Fully close the manual shutoff valve of the crew oxygen-storage cylinder (5750HM).
(2) Put the WARNING NOTICE(S) in position to tell persons not to open the manual shutoff valve of the crew oxygen-storage cylinder (5750HM).
Subtask 35-12-81-870-050-A ** ON A/C NOT FOR ALL (1) Fully close the manual shutoff valve of the crew oxygen-storage cylinder (5750HM).
(2) Put the WARNING NOTICE(S) in position to tell persons not to open the manual shutoff valve of the crew oxygen-storage cylinder (5750HM).
E. Bleeding of the Oxygen System
(1) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Push the CREW SUPPLY pushbutton switch (the OFF legend goes off).
(2) On one of the oxygen-mask stowage box, push and hold the PRESS TO TEST AND RESET control button. At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regulator:
(a) Keep the PRESS TO TEST AND RESET control button and the PRESS TO TEST/EMERGENCY knob pushed for a minimum of three seconds.
(3) Do this bleeding procedure for all the oxygen-mask stowage boxes.
(4) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Release the CREW SUPPLY pushbutton switch (the OFF legend comes on).
(b) Put a WARNING NOTICE(S) in position to tell persons not to push the CREW SUPPLY pushbutton switch.
Subtask 35-12-81-860-052-B ** ON A/C NOT FOR ALL (1) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Push the CREW SUPPLY pushbutton switch (the OFF legend goes off).
(2) On one of the oxygen-mask stowage box, push and hold the PRESS TO TEST AND RESET control button. At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regulator:
(a) Keep the PRESS TO TEST AND RESET control button and the PRESS TO TEST/EMERGENCY knob pushed for a minimum of three seconds.
NOTE: During this time, the flow rate indicator changes from yellow to black and the volume of the sound of the oxygen flow decreases.
(b) When the flow rate indicator is black and when you no longer hear the sound of the oxygen flow:- Release the PRESS TO TEST/EMERGENCY knob.
- Release the PRESS TO TEST AND RESET control button.
WARNING:
MAKE SURE THAT THE PRESS TO TEST/EMERGENCY KNOB IS NOT IN THE EMERGENCY POSITION. IF IT IS IN THE EMERGENCY POSITION, THERE CAN BE A LEAK OF OXYGEN.
(c) Make sure that the PRESS TO TEST/EMERGENCY knob is not in the EMERGENCY position.(3) Do this bleeding procedure for all the oxygen-mask stowage boxes.
(4) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Release the CREW SUPPLY pushbutton switch (the OFF legend comes on).
(b) Put a WARNING NOTICE(S) in position to tell persons not to push the CREW SUPPLY pushbutton switch.
F. Aircraft Maintenance Configuration
(1) Fully close the manual shutoff valves of the crew oxygen-storage cylinders (5750HM1 and 5750HM2).
(2) Put the WARNING NOTICE(S) in position to tell persons not to open the manual shutoff valves of the crew oxygen-storage cylinders (5750HM1 and 5750HM2).
Subtask 35-12-81-870-050-B ** ON A/C NOT FOR ALL (1) Fully close the manual shutoff valves of the crew oxygen-storage cylinders (5750HM1 and 5750HM2).
(2) Put the WARNING NOTICE(S) in position to tell persons not to open the manual shutoff valves of the crew oxygen-storage cylinders (5750HM1 and 5750HM2).
G. Bleeding of the Oxygen System(s)
(1) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Push the CREW SUPPLY pushbutton switch (the OFF legend goes off).
(2) FOR [5753HM1] (MANIFOLD DISTRIBUTION)
(a) On the captain oxygen-mask stowage-box, push and hold the PRESS TO TEST AND RESET control button. At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regulator:
1 Keep the PRESS TO TEST AND RESET control button and the PRESS TO TEST/EMERGENCY knob pushed for a minimum of three seconds.
(3) FOR [5753HM2] (MANIFOLD DISTRIBUTION)
(a) On the first-officer oxygen-mask stowage-box, push and hold the PRESS TO TEST AND RESET control button. At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regulator:
1 Keep the PRESS TO TEST AND RESET control button and the PRESS TO TEST/EMERGENCY knob pushed for a minimum of three seconds.
(4) Do this bleeding procedure for all the oxygen-mask stowage boxes.
(5) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Release the CREW SUPPLY pushbutton switch (the OFF legend comes on).
(b) Put a WARNING NOTICE(S) in position to tell persons not to push the CREW SUPPLY pushbutton switch.
Subtask 35-12-81-865-052-A (1) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Push the CREW SUPPLY pushbutton switch (the OFF legend goes off).
(2) FOR [5753HM1] (MANIFOLD DISTRIBUTION)
(a) On the captain oxygen-mask stowage-box, push and hold the PRESS TO TEST AND RESET control button. At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regulator:
1 Keep the PRESS TO TEST AND RESET control button and the PRESS TO TEST/EMERGENCY knob pushed for a minimum of three seconds.
NOTE: During this time, the flow rate indicator changes from yellow to black and the volume of the sound of the oxygen flow decreases.
2 When the flow rate indicator is black and when you no longer hear the sound of the oxygen flow:- Release the PRESS TO TEST/EMERGENCY knob.
- Release the PRESS TO TEST AND RESET control button.
WARNING:
MAKE SURE THAT THE PRESS TO TEST/EMERGENCY KNOB IS NOT IN THE EMERGENCY POSITION. IF IT IS IN THE EMERGENCY POSITION, THERE CAN BE A LEAK OF OXYGEN.
3 Make sure that the PRESS TO TEST/EMERGENCY knob is not in the EMERGENCY position. (3) FOR [5753HM2] (MANIFOLD DISTRIBUTION)
(a) On the first-officer oxygen-mask stowage-box, push and hold the PRESS TO TEST AND RESET control button. At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regulator:
1 Keep the PRESS TO TEST AND RESET control button and the PRESS TO TEST/EMERGENCY knob pushed for a minimum of three seconds.
NOTE: During this time, the flow rate indicator changes from yellow to black and the volume of the sound of the oxygen flow decreases.
2 When the flow rate indicator is black and when you no longer hear the sound of the oxygen flow:- Release the PRESS TO TEST/EMERGENCY knob.
- Release the PRESS TO TEST AND RESET control button.
WARNING:
MAKE SURE THAT THE PRESS TO TEST/EMERGENCY KNOB IS NOT IN THE EMERGENCY POSITION. IF IT IS IN THE EMERGENCY POSITION, THERE CAN BE A LEAK OF OXYGEN.
3 Make sure that the PRESS TO TEST/EMERGENCY knob is not in the EMERGENCY position.(4) Do this bleeding procedure for all the oxygen-mask stowage boxes.
(5) In the cockpit, on the overhead panel, on the OXYGEN section of panel 21VU:
(a) Release the CREW SUPPLY pushbutton switch (the OFF legend comes on).
(b) Put a WARNING NOTICE(S) in position to tell persons not to push the CREW SUPPLY pushbutton switch.
H. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | OXYGEN/CREW/OXY/SPLY | 1HT | HA01 |
CAUTION:
PUT DRY AND CLEAN METAL OR PLASTIC PLUGS ON ALL PIPES OR UNITS THAT YOU REMOVE TEMPORARILY. THEN PUT EACH PIPE OR UNIT IN A SEALED VINYL BAG. IF YOU DO NOT OBEY THESE INSTRUCTIONS, CONTAMINATION OF THE OXYGEN SYSTEM CAN OCCUR.
Subtask 35-12-81-000-050-A ** ON A/C NOT FOR ALL A. Removal of the Oxygen Distribution Manifold
(1) Disconnect the electrical connector (10):
(b) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(2) If installed, remove the OXYGEN CLEAN sticker from the oxygen inlet port (5), the oxygen outlet port (7) and the LP oxygen pressure-switch (11).
(4) Disconnect the oxygen inlet port (5) and the oxygen outlet port (7) from the oxygen distribution manifold (1).
(5) Remove and discard the rings (9).
(6) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN and a BAG - VINYL on the disconnected line ends.
(7) Hold the oxygen distribution manifold (1) and remove the bolts (2) and the washers (3).
(8) Remove the oxygen distribution manifold (1) from its support (4).
(9) If necessary, remove the LP oxygen pressure-switch (11) from the oxygen distribution manifold (1) (Ref. AMM TASK 35-13-14-000-001).
(10) Put the oxygen distribution manifold (1) in a BAG - VINYL.
Subtask 35-12-81-000-050-B ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (10):
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(a) Disconnect the electrical connector (10) from the LP oxygen pressure-switch (11).(b) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(2) If installed, remove the OXYGEN CLEAN sticker from the oxygen inlet port (5), the oxygen outlet port (7) and the LP oxygen pressure-switch (11).
NOTE: It is not necessary to install a new OXYGEN CLEAN stickers.
(3) Disconnect the coupling nuts (6) and (8).(4) Disconnect the oxygen inlet port (5) and the oxygen outlet port (7) from the oxygen distribution manifold (1).
(5) Remove and discard the rings (9).
(6) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN and a BAG - VINYL on the disconnected line ends.
(7) Hold the oxygen distribution manifold (1) and remove the bolts (2) and the washers (3).
(8) Remove the oxygen distribution manifold (1) from its support (4).
(9) If necessary, remove the LP oxygen pressure-switch (11) from the oxygen distribution manifold (1) (Ref. AMM TASK 35-13-14-000-001).
(10) Put the oxygen distribution manifold (1) in a BAG - VINYL.
A. Removal of Oxygen Distribution Manifold
(1) FOR [5753HM1] (MANIFOLD DISTRIBUTION)
(a) Disconnect the electrical connector (2):
2 Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(b) If installed, remove the OXYGEN CLEAN sticker from the oxygen inlet port (8), the oxygen outlet ports (11) and the LP oxygen pressure-switch (3).
(d) Disconnect the oxygen inlet port (8) and the oxygen outlet ports (11) from the oxygen distribution manifold (4).
(e) Remove and discard the rings (9).
(f) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN and a BAG - VINYL on the disconnected line ends.
(g) Hold the oxygen distribution manifold (4) and remove the bolts (5) and the washers (6).
(h) Remove the oxygen distribution manifold (4) from its support (1).
(i) If necessary, remove the LP oxygen pressure-switch (3) from the oxygen distribution manifold (4) (Ref. AMM TASK 35-13-14-000-802).
(j) Put the oxygen distribution manifold (4) in a BAG - VINYL.
(2) FOR [5753HM2] (MANIFOLD DISTRIBUTION)
(a) Disconnect the electrical connector (2):
2 Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(b) If installed, remove the OXYGEN CLEAN sticker from the oxygen inlet port (8), the oxygen outlet ports (11) and the LP oxygen pressure-switch (3).
(d) Disconnect the oxygen inlet port (8) and the oxygen outlet ports (11) from the oxygen distribution manifold (4).
(e) Remove and discard the rings (9).
(f) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN and a BAG - VINYL on the disconnected line ends.
(g) Hold the oxygen distribution manifold (4) and remove the bolts (5) and the washers (6).
(h) Remove the oxygen distribution manifold (4) from its support (12).
(i) If necessary, remove the LP oxygen pressure-switch (3) from the oxygen distribution manifold (4) (Ref. AMM TASK 35-13-14-000-802).
(j) Put the oxygen distribution manifold (4) in a BAG - VINYL.
(1) FOR [5753HM1] (MANIFOLD DISTRIBUTION)
(a) Disconnect the electrical connector (2):
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
1 Disconnect the electrical connector (2) from the LP oxygen pressure-switch (3).2 Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(b) If installed, remove the OXYGEN CLEAN sticker from the oxygen inlet port (8), the oxygen outlet ports (11) and the LP oxygen pressure-switch (3).
NOTE: It is not necessary to install a new OXYGEN CLEAN stickers.
(c) Disconnect the coupling nuts (7) and (10).(d) Disconnect the oxygen inlet port (8) and the oxygen outlet ports (11) from the oxygen distribution manifold (4).
(e) Remove and discard the rings (9).
(f) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN and a BAG - VINYL on the disconnected line ends.
(g) Hold the oxygen distribution manifold (4) and remove the bolts (5) and the washers (6).
(h) Remove the oxygen distribution manifold (4) from its support (1).
(i) If necessary, remove the LP oxygen pressure-switch (3) from the oxygen distribution manifold (4) (Ref. AMM TASK 35-13-14-000-802).
(j) Put the oxygen distribution manifold (4) in a BAG - VINYL.
(2) FOR [5753HM2] (MANIFOLD DISTRIBUTION)
(a) Disconnect the electrical connector (2):
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
1 Disconnect the electrical connector (2) from the LP oxygen pressure-switch (3).2 Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(b) If installed, remove the OXYGEN CLEAN sticker from the oxygen inlet port (8), the oxygen outlet ports (11) and the LP oxygen pressure-switch (3).
NOTE: It is not necessary to install a new OXYGEN CLEAN stickers.
(c) Disconnect the coupling nuts (7) and (10).(d) Disconnect the oxygen inlet port (8) and the oxygen outlet ports (11) from the oxygen distribution manifold (4).
(e) Remove and discard the rings (9).
(f) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN and a BAG - VINYL on the disconnected line ends.
(g) Hold the oxygen distribution manifold (4) and remove the bolts (5) and the washers (6).
(h) Remove the oxygen distribution manifold (4) from its support (12).
(i) If necessary, remove the LP oxygen pressure-switch (3) from the oxygen distribution manifold (4) (Ref. AMM TASK 35-13-14-000-802).
(j) Put the oxygen distribution manifold (4) in a BAG - VINYL.
Oxygen Distribution Manifold