W DOC AIRBUS | AMM A320F

Operational Test of the Wheel Well Lighting


TASK 33-37-00-710-001-A
Operational Test of the Wheel Well Lighting


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
FIN: 10LL ** ON A/C NOT FOR ALL
FIN: 12LL
FIN: 7LL
FIN: 8LL
FIN: 9LL ** ON A/C NOT FOR ALL
1. Reason for the Job
To make sure that the wheel well lighting operates correctly.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
460005835
2
SLEEVE - GROUND LOCK
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
191MB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 29-10-00-863-002-A
Pressurize the Yellow Hydraulic System with a Hydraulic Ground Power-Cart
TASK 29-10-00-864-001-A
Depressurize the Green Hydraulic System
TASK 29-10-00-864-002-A
Depressurize the Yellow Hydraulic System
TASK 29-10-00-864-003-A
Depressurize the Blue Hydraulic System
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
3. Job Set-up
Subtask 33-37-00-861-050-A
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 33-37-00-865-050-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VULIGHTING/WHL WELL/LTG/DOME2LLX08
Subtask 33-37-00-010-050-A
C. Get Access
   (1) Open the main gear doors for access (Ref. AMM TASK 32-12-00-010-001).
   (2) Depressurize the Green, Yellow and Blue hydraulic systems (Ref. AMM TASK 29-10-00-864-001) (Ref. AMM TASK 29-10-00-864-002) (Ref. AMM TASK 29-10-00-864-003).
   (3) Install the 460005835 SLEEVE - GROUND LOCK on the main-gear door actuator.
     (a) FOR [12LL] (SW-LT ON)

   (4) Open the access panel 191MB.
   (5) Put the WARNING NOTICE(S) in position.
4. Procedure
Subtask 33-37-00-710-050-A ** ON A/C NOT FOR ALL
A. Test of the Wheel Well Lighting
   (1) Do this test.
ACTION
RESULT
1.On the electrical combination panel 2025VU:
  • set the control switch 12LL to the ON position.
In the MLG wheel well:

  • the wheel well lights 7LL and 8LL come on.
    In the hydraulic compartment:
  • the hydraulic compartment lights 9LL and 10LL come on.
  • set the control switch 12LL to the OFF position.
  • the hydraulic compartment lights 9LL and 10LL go off.
    In the MLG wheel well:
  • the wheel well lights 7LL and 8LL go off.
Subtask 33-37-00-710-050-B ** ON A/C NOT FOR ALL
A. Test of the Wheel Well Lighting
   (1) Do this test.
ACTION
RESULT
1.On the electrical combination panel 2025VU:
In the MLG wheel well:
  • set the control switch 12LL to the ON position.
  • the wheel well lights 7LL and 8LL come on.
  • set the control switch 12LL to the OFF position.
  • the wheel well lights 7LL and 8LL go off.
5. Close-up
Subtask 33-37-00-410-050-A
A. Close Access
   (1) Remove the 460005835 SLEEVE - GROUND LOCK from the main-gear door actuator (Ref. AMM TASK 32-12-00-410-001).
   (2) Pressurize the Yellow hydraulic system to close the main gear doors (Ref. AMM TASK 29-10-00-863-002).
   (3) Close the main gear doors (Ref. AMM TASK 32-12-00-410-001).
   (4) Close the access panel 191MB.
   (5) Remove the WARNING NOTICE(S).
   (6) Make sure that the work area is clean and clear of tools and other items.
Subtask 33-37-00-862-050-A
B. De-energize the aircraft electrical circuit (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 12:33:17 UTC