W DOC AIRBUS | AMM A320F

Operational Test of the Service Area Lighting


TASK 33-31-00-710-001-A
Operational Test of the Service Area Lighting


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
FIN: 4LJ
FIN: 5LJ
FIN: 6LJ
1. Reason for the Job
To make sure that the service area lighting operates correctly.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [4LJ] (MAINT. LIGHT)
FOR [5LJ] (MAINT. LIGHT)
312AR
FOR [6LJ] (MAINT. LIGHT)
315AL
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 33-31-00-861-050-A
A. Energize the aircraft electrical circuit. (Ref. AMM TASK 24-41-00-861-002)
Subtask 33-31-00-865-052-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VULIGHT-SEC191LJE07
** ON A/C ALL
2001VULIGHT-APU2LJE08
** ON A/C NOT FOR ALL
2001VULIGHT/SEC191LJE07
Subtask 33-31-00-010-050-A
C. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position:
     (a) FOR [4LJ] (MAINT. LIGHT), [5LJ] (MAINT. LIGHT)
in Zone 312.
     (b) FOR [6LJ] (MAINT. LIGHT)
below the APU compartment.
   (2) Open the access door:
     (a) FOR [4LJ] (MAINT. LIGHT), [5LJ] (MAINT. LIGHT)
open 312AR.
     (b) FOR [6LJ] (MAINT. LIGHT)
open 315AL.
4. Procedure
Subtask 33-31-00-710-050-A
A. Test of the Service Area Lighting.
   (1) Do this test.
ACTION
RESULT
1.In the section 19 service area:
In the section 19 service area:
  • set the control switch 3LJ to the ON position.
  • the service area lights 4LJ and 5LJ come on.
  • set the control switch 3LJ to the OFF position.
  • the service area lights 4LJ and 5LJ go off.
2.In the APU compartment:
In the APU compartment:
  • set the control switch 11LJ to the ON position.
  • the service area light 6LJ comes on.
  • set the control switch 11LJ to the OFF position.
  • the service area light 6LJ goes off.
5. Close-up
Subtask 33-31-00-410-050-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door:
     (a) FOR [4LJ] (MAINT. LIGHT), [5LJ] (MAINT. LIGHT)
close 312AR.
     (b) FOR [6LJ] (MAINT. LIGHT)
close 315AL.
   (3) Remove the access platform(s).
Subtask 33-31-00-862-050-A
B. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 12:33:13 UTC