Uploading of the Database of the Data Loading Selector Unit (DLSU)
TASK 31-38-00-610-805-A
Uploading of the Database of the Data Loading Selector Unit (DLSU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 31-38-00-861-077-A ** ON A/C NOT FOR ALL Subtask 31-38-00-860-117-A ** ON A/C NOT FOR ALL
Subtask 31-38-00-610-053-A ** ON A/C NOT FOR ALL
Subtask 31-38-00-080-070-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 08:39:40 UTC
Uploading of the Database of the Data Loading Selector Unit (DLSU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| ALT45200001 | 1 | PORTABLE DATA LOADER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 31-38-00-861-077-A ** ON A/C NOT FOR ALL Subtask 31-38-00-860-117-A ** ON A/C NOT FOR ALL
B. Prepare the media disk(s).
(1) Get the media disk(s) from the storage box in the cockpit.
(2) Make sure that the Part Number (P/N) on the media disk(s) is(are) the same as the P/N given in the airline configuration management document.
(3) If the media disk(s) is(are) not available or not the correct one(s), contact your airline engineering department to get the correct part number(s) applicable to the aircraft.
Subtask 31-38-00-480-053-A ** ON A/C NOT FOR ALL (1) Get the media disk(s) from the storage box in the cockpit.
(2) Make sure that the Part Number (P/N) on the media disk(s) is(are) the same as the P/N given in the airline configuration management document.
(3) If the media disk(s) is(are) not available or not the correct one(s), contact your airline engineering department to get the correct part number(s) applicable to the aircraft.
C. Installation of the Portable Data Loader (PDL)
(1) On the ALT45200001 PORTABLE DATA LOADER, make sure that the ON/OFF switch is in the OFF position.
(2) On center pedestal 11VU, on the Data Loading Selector Unit (DLSU):
Subtask 31-38-00-865-105-A ** ON A/C NOT FOR ALL (1) On the ALT45200001 PORTABLE DATA LOADER, make sure that the ON/OFF switch is in the OFF position.
(2) On center pedestal 11VU, on the Data Loading Selector Unit (DLSU):
- Remove the PDL plug cap from the data loader connector on the front face of the DLSU.
- Connect the PDL cable to the ALT45200001 PORTABLE DATA LOADER and to the data loader connector on the front face of the DLSU.
D. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-38-00-860-122-A ** ON A/C NOT FOR ALL Subtask 31-38-00-860-119-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | DATA/LOADER/SPLY | 3TD | J16 |
| 121VU | DLSU &/DLRB/SPLY | 5TD | J15 |
| 121VU | PDL/PWR/SPLY | 14TD | K19 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | PDL/PWR/SPLY | 14TD | J45 |
| 121VU | DATA/LOADER/SPLY | 3TD | J39 |
| 121VU | DLSU &/DLRB/SPLY | 5TD | J38 |
F. Make sure that the Aircraft is in the Ground Configuration
Subtask 31-38-00-280-074-A ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the ECAM control panel:
| On the lower ECAM DU:
|
G. Check of the Database Software Number before the Uploading into the DLSU
(1) Make sure that the database software number given on the LCD screen of the DLSU is different from the digits of the software P/N reference on the media disk(s).
Subtask 31-38-00-280-074-B ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On center pedestal 11VU, on the DLSU:
| On the display of the DLSU the indication that follows comes into view:
NOTE: The XXXXXXXXXX indication is the existing database software PN installed in the DLSU. Default value: '----------'. |
G. Check of the Database Software Number before the Uploading into the DLSU
(1) Make sure that the database software PN shown on the LCD display of the DLSU is different from the database software PN given by the airline configuration-management document.
4. Procedure| ACTION | RESULT |
|---|---|
1.On center pedestal 11VU, on the DLSU:
| On the display of the DLSU the indication that follows comes into view:
NOTE: The XXXXXXXXXX indication is the existing database software PN installed in the DLSU. Default value: '----------'. |
Subtask 31-38-00-610-053-A ** ON A/C NOT FOR ALL
A. Uploading of the Database of the DLSU
Subtask 31-38-00-610-053-B ** ON A/C NOT FOR ALL NOTE: If the PDL has the digital signature check, it can send two messages:
- One message, if the PDL detects that the software has no signature. You can ignore this message, because it has no effect on the aircraft software uploading, or
- One message, if the PDL detects an incorrect or corrupt signature. If this occurs, the software uploading is not possible and you must use a different software.
Because of data security, Airbus recommends that you send a report of the fault to the aircraft-security focal point.
| ACTION | RESULT |
|---|---|
1.On center pedestal 11VU, on the DLSU:
| The DLSU starts the self-test. |
| 2.Make sure that no error message comes into view. | On the display of the DLSU, the indication that follows comes into view:
|
3.On center pedestal 11VU, on the DLSU:
| On the display of the DLSU, the indication that follows comes into view:
|
4.On center pedestal 11VU, on the DLSU:
| On the display of the DLSU, the indication that follows comes into view:
NOTE: If no PDL is connected, the indication that follows comes into view:
|
5.On the PDL:
| |
| 6.Make sure that you upload all the necessary software from all the media disk. | |
7.On center pedestal 11VU, on the DLSU:
| On the display of the DLSU, the indication that follows comes into view:
|
| | On center pedestal 11VU, on the display of the DLSU, the indication that follows comes into view:
NOTE: The ZZZZZZZZZZZ indication is the database software P/N installed in the DLSU. |
8.On the display of the DLSU:
| |
9.On center pedestal 11VU, on the DLSU:
| On the display of the DLSU, the indication goes out of view. |
A. Uploading of the Database of the DLSU
5. Close-upNOTE: If the PDL has the digital signature check, it can send two messages:
- One message, if the PDL detects that the software has no signature. You can ignore this message, because it has no effect on the aircraft software uploading, or
- One message, if the PDL detects an incorrect or corrupt signature. If this occurs, the software uploading is not possible and you must use a different software.
Because of data security, Airbus recommends that you send a report of the fault to the aircraft-security focal point.
| ACTION | RESULT |
|---|---|
1.On center pedestal 11VU, on the DLSU:
| The DLSU starts the self-test. |
| 2.Make sure that no error message comes into view. | On the display of the DLSU, the indication that follows comes into view:
|
3.On center pedestal 11VU, on the DLSU:
| On the display of the DLSU, the indication that follows comes into view:
|
4.On center pedestal 11VU, on the DLSU:
| On the display of the DLSU, the indication that follows comes into view:
NOTE: If no PDL is connected, the indication that follows comes into view:
|
5.On the PDL:
| |
6.On center pedestal 11VU, on the DLSU:
| On the display of the DLSU, the indication that follows comes into view:
|
| | On center pedestal 11VU, on the display of the DLSU, the indication that follows comes into view:
NOTE: The ZZZZZZZZZZZ indication is the database software P/N installed in the DLSU. |
7.On the display of the DLSU:
| |
8.On center pedestal 11VU, on the DLSU:
| On the display of the DLSU, the indication goes out of view. |
Subtask 31-38-00-080-070-A ** ON A/C NOT FOR ALL
A. Removal of the PDL
(1) Stop the ALT45200001 PORTABLE DATA LOADER (refer to PDL user guide).
(2) On center pedestal 11VU:
Subtask 31-38-00-860-118-A ** ON A/C NOT FOR ALL (1) Stop the ALT45200001 PORTABLE DATA LOADER (refer to PDL user guide).
(2) On center pedestal 11VU:
- Disconnect the PDL cable from the PDL and from the data loader connector on the front face of the DLSU.
- Install the PDL plug cap on the data loader connector on the front face of the DLSU.
B. Put the aircraft back to its initial configuration.
(1) Put the media disk(s) back into the storage box in the cockpit.
Subtask 31-38-00-862-075-A ** ON A/C NOT FOR ALL (1) Put the media disk(s) back into the storage box in the cockpit.