Read the AVIONICS STATUS on the MCDU
TASK 31-32-00-740-009-A
Read the AVIONICS STATUS on the MCDU
To get the AVIONICS STATUS page on the ground. This page gives a real-time list of the units or systems for which:
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 31-32-00-861-081-A
Subtask 31-32-00-740-058-A
Subtask 31-32-00-860-117-A
[Rev.10 from 2021]
2026.04.01 08:28:58 UTC
Read the AVIONICS STATUS on the MCDU
ZONE: 210
1. Reason for the JobTo get the AVIONICS STATUS page on the ground. This page gives a real-time list of the units or systems for which:
- there is an internal or external Class 1 or 2 fault (for example: AFS).
- there is an internal or external Class 3 fault. The (CLASS 3) indication is shown near the name of the unit (for example: AEVC (CLASS 3)).
- no valid data is available. For this, the indication is NO X DATA in which X is the name of the unit or system (for example: NO ATSU DATA).
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 31-32-00-861-081-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) On the overhead panel, make sure that:
(a) The ON legend of the APU/MASTER SW, ENG/FADEC GND PWR/1 and ENG/FADEC GND PWR/2 pushbutton switches is on.
(b) The OFF or FAULT legend of the ELEC/BAT 1, ELEC/BAT 2, ADR 1, ADR 2 and ADR 3 pushbutton switches is not on.
(c) The OFF/NAV/ATT selector switches related to the IR 1, IR 2 and IR 3 are at NAV.
Subtask 31-32-00-865-087-A (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) On the overhead panel, make sure that:
(a) The ON legend of the APU/MASTER SW, ENG/FADEC GND PWR/1 and ENG/FADEC GND PWR/2 pushbutton switches is on.
(b) The OFF or FAULT legend of the ELEC/BAT 1, ELEC/BAT 2, ADR 1, ADR 2 and ADR 3 pushbutton switches is not on.
(c) The OFF/NAV/ATT selector switches related to the IR 1, IR 2 and IR 3 are at NAV.
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AUTO FLT/MCDU/1 | 11CA1 | B01 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | AUTO FLT/MCDU/1 | 11CA1 | H07 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | CFDS/CFDIU/SPLY | 2TW | J18 |
| 121VU | CFDS/CFDIU/BACK/UP | 8TW | J17 |
| ** ON A/C ALL | |||
| 121VU | AUTO FLT/MCDU/2 | 11CA2 | N20 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | CFDS/CFDIU/SPLY | 2TW | J41 |
| 121VU | CFDS/CFDIU/BACK/UP | 8TW | J40 |
Subtask 31-32-00-740-058-A
A. Do this procedure:
5. Close-up| ACTION | RESULT |
|---|---|
| 1.Adjust the brightness of the MCDU screen: | The MCDU is on. |
2.On the MCDU:
| On the MCDU:
|
3.On the MCDU:
| On the MCDU:
|
4.On the MCDU:
| On the MCDU:
|
Subtask 31-32-00-860-117-A
A. Put the aircraft back to its initial configuration.
(1) On the MCDU, push the line key adjacent to the RETURN indication until the CFDS MENU page comes into view.
(2) Fully decrease the brightness of the MCDU screen (display off).
(3) On the overhead panel:
(a) set the OFF/NAV/ATT selector switches related to the IR 1, IR 2 and IR 3 to OFF.
(b) Set the APU/MASTER SW, ELEC/BAT 1, ELEC/BAT 2, ADR 1, ADR 2, ADR 3, ENG/FADEC GND PWR/1 and ENG/FADEC GND PWR/2 pushbutton switches to OFF.
(4) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) On the MCDU, push the line key adjacent to the RETURN indication until the CFDS MENU page comes into view.
(2) Fully decrease the brightness of the MCDU screen (display off).
(3) On the overhead panel:
(a) set the OFF/NAV/ATT selector switches related to the IR 1, IR 2 and IR 3 to OFF.
(b) Set the APU/MASTER SW, ELEC/BAT 1, ELEC/BAT 2, ADR 1, ADR 2, ADR 3, ENG/FADEC GND PWR/1 and ENG/FADEC GND PWR/2 pushbutton switches to OFF.
(4) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).