Reactivation of the Heating of the Pilot Probes, Static Probes, Angle of Attack Sensors and of the Probe Heat Computer (PHC)
TASK 30-31-00-440-002-A
Reactivation of the Heating of the Pilot Probes, Static Probes, Angle of Attack Sensors and of the Probe Heat Computer (PHC)
1. Reason for the Job
MMEL 30-31-01B
PROBE HEAT COMPUTER (PHC)
MMEL 30-31-01C
PROBE HEAT COMPUTER (PHC)
MMEL 30-31-03B
STATIC PORTS HEATER
MMEL 30-31-03C
STATIC PORTS HEATER
MMEL 30-31-03D
STATIC PORTS HEATER
MMEL 30-31-04A
ANGLE OF ATTACK (AOA) PROBES HEATING
MMEL 30-31-04B
ANGLE OF ATTACK (AOA) PROBES HEATING
MMEL 30-31-04C
ANGLE OF ATTACK (AOA) PROBES HEATING
MMEL 30-31-02A
PITOT HEATER
MMEL 30-31-02B
PITOT HEATER
MMEL 30-31-02C
PITOT HEATER
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 30-31-00-861-055-A Subtask 30-31-00-941-055-A
Subtask 30-31-00-810-051-A
Subtask 30-31-00-862-055-A
[Rev.10 from 2021]
2026.04.01 00:30:43 UTC
Reactivation of the Heating of the Pilot Probes, Static Probes, Angle of Attack Sensors and of the Probe Heat Computer (PHC)
1. Reason for the Job
MMEL 30-31-01B
PROBE HEAT COMPUTER (PHC)
MMEL 30-31-01C
PROBE HEAT COMPUTER (PHC)
MMEL 30-31-03B
STATIC PORTS HEATER
MMEL 30-31-03C
STATIC PORTS HEATER
MMEL 30-31-03D
STATIC PORTS HEATER
MMEL 30-31-04A
ANGLE OF ATTACK (AOA) PROBES HEATING
MMEL 30-31-04B
ANGLE OF ATTACK (AOA) PROBES HEATING
MMEL 30-31-04C
ANGLE OF ATTACK (AOA) PROBES HEATING
MMEL 30-31-02A
PITOT HEATER
MMEL 30-31-02B
PITOT HEATER
MMEL 30-31-02C
PITOT HEATER
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 30-31-00-861-055-A Subtask 30-31-00-941-055-A
B. Aircraft Maintenance Configuration
(1) On the OVERHEAD CTL & IND Panel 25VU:
4. Procedure(1) On the OVERHEAD CTL & IND Panel 25VU:
- push the PROBE/WINDOW HEAT pushbutton switch (the ON legend comes on).
Subtask 30-31-00-810-051-A
A. Reactivation of the Heating of the Pitot Probes
(1) On the OVERHEAD CTL & IND Panel 25VU:
5. Close-up(1) On the OVERHEAD CTL & IND Panel 25VU:
- Release the PROBE/WINDOW HEAT pushbutton switch (AUTO).
- The ON legend of the PROBE/WINDOW HEAT pushbutton switch goes off.
Subtask 30-31-00-862-055-A