1. Reason for the Job
MMEL 30-31-01B
PROBE HEAT COMPUTER (PHC)
MMEL 30-31-01C
PROBE HEAT COMPUTER (PHC)
MMEL 30-31-03B
STATIC PORTS HEATER
MMEL 30-31-03C
STATIC PORTS HEATER
MMEL 30-31-03D
STATIC PORTS HEATER
MMEL 30-31-04A
ANGLE OF ATTACK (AOA) PROBES HEATING
MMEL 30-31-04B
ANGLE OF ATTACK (AOA) PROBES HEATING
MMEL 30-31-04C
ANGLE OF ATTACK (AOA) PROBES HEATING
MMEL 30-31-02A
PITOT HEATER
MMEL 30-31-02B
PITOT HEATER
MMEL 30-31-02C
PITOT HEATER
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 30-31-00-861-055-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 30-31-00-941-055-A
B. Aircraft Maintenance Configuration
   (1) On the OVERHEAD CTL & IND Panel 25VU:
  • push the PROBE/WINDOW HEAT pushbutton switch (the ON legend comes on).
4. Procedure
Subtask 30-31-00-810-051-A
A. Reactivation of the Heating of the Pitot Probes
   (1) On the OVERHEAD CTL & IND Panel 25VU:
  • Release the PROBE/WINDOW HEAT pushbutton switch (AUTO).
  • The ON legend of the PROBE/WINDOW HEAT pushbutton switch goes off.
5. Close-up
Subtask 30-31-00-862-055-A
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).