W DOC AIRBUS | AMM A320F

Deactivation of the Yellow Electric Pump


TASK 29-24-00-040-001-A
Deactivation of the Yellow Electric Pump


WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
FIN: 3075GX
Task Summary
Access Test Specific Tools Mhr E/T Nb Men
NONONO0.30.31
1. Reason for the Job
MMEL 29-24-01A
YELLOW SYSTEM ELECTRIC PUMP (FAA ONLY)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 29-24-00-860-058-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that the YELLOW ELEC PUMP pushbutton switch 3804GX on the overhead panel 40VU is in the OFF position (the ON legend is off).
4. Procedure
CAUTION: IMMEDIATELY OPEN THE CIRCUIT BREAKERS FOR THE YELLOW HYDRAULIC SYSTEM AFTER THE CARGO COMPARTMENT DOOR IS FULLY CLOSED/OPEN. IF THE YELLOW HYDRAULIC PUMP OPERATES ON THE GROUND FOR TOO LONG, DAMAGE TO THE YELLOW HYDRAULIC SYSTEM WILL OCCUR.
NOTE: It is permitted to close the circuit breakers only for the operation of the cargo doors.
Subtask 29-24-00-865-053-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUDOORS/CARGO1MJT12
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
Subtask 29-24-00-941-051-A
B. Put a warning notice in the flight compartment to tell the crew that the Yellow electric pump does not operate.
5. Close-up
Subtask 29-24-00-862-053-A
A. Aircraft Maintenance Configuration
   (1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
   (2) Make an entry in the logbook.
[Rev.10 from 2021] 2026.04.01 00:26:53 UTC