Deactivation of the Yellow Electric Pump
TASK 29-24-00-040-001-A
Deactivation of the Yellow Electric Pump
MMEL 29-24-01A
YELLOW SYSTEM ELECTRIC PUMP (FAA ONLY)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 29-24-00-860-058-A
Subtask 29-24-00-862-053-A
[Rev.10 from 2021]
2026.04.01 00:26:53 UTC
Deactivation of the Yellow Electric Pump
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
1. Reason for the JobMMEL 29-24-01A
YELLOW SYSTEM ELECTRIC PUMP (FAA ONLY)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 29-24-00-860-058-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the YELLOW ELEC PUMP pushbutton switch 3804GX on the overhead panel 40VU is in the OFF position (the ON legend is off).
4. Procedure(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the YELLOW ELEC PUMP pushbutton switch 3804GX on the overhead panel 40VU is in the OFF position (the ON legend is off).
CAUTION:
IMMEDIATELY OPEN THE CIRCUIT BREAKERS FOR THE YELLOW HYDRAULIC SYSTEM AFTER THE CARGO COMPARTMENT DOOR IS FULLY CLOSED/OPEN. IF THE YELLOW HYDRAULIC PUMP OPERATES ON THE GROUND FOR TOO LONG, DAMAGE TO THE YELLOW HYDRAULIC SYSTEM WILL OCCUR.
NOTE: It is permitted to close the circuit breakers only for the operation of the cargo doors.
Subtask 29-24-00-865-053-A A. Open, safety and tag this(these) circuit breaker(s):
Subtask 29-24-00-941-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | DOORS/CARGO | 1MJ | T12 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
B. Put a warning notice in the flight compartment to tell the crew that the Yellow electric pump does not operate.
5. Close-upSubtask 29-24-00-862-053-A
A. Aircraft Maintenance Configuration
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(2) Make an entry in the logbook.
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(2) Make an entry in the logbook.