Removal of the Damper
TASK 29-13-53-000-801-A
Removal of the Damper
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 29-13-53-941-050-A ** ON A/C NOT FOR ALL
Subtask 29-13-53-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:24:00 UTC
Removal of the Damper
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
FIN: 3600GM ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | 1 | CONTAINER 1 L (1/4 USGAL) |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 98D27803000000 | 1 | LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 673CB, 673EB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-29-00-911-002-A | Removal/Installation of an O-ring (Hydraulic Systems) |
| TASK 27-00-00-480-002-A | Installation of the Flap/Slat Control-Lever Locking Tool (98D27803000000) |
| TASK 27-50-00-866-008-A | Extension of the Flaps on the Ground |
| TASK 27-50-00-866-008-A-01 | Extension of the Flaps/Slats on the Ground |
| TASK 29-00-00-910-002-A | Safety Procedures of the Hydraulic System |
| TASK 29-10-00-864-002-A | Depressurize the Yellow Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 29-23-00-860-001-A | Disconnection of the Isolation Coupling of the Power Transfer Unit (PTU) |
| TASK 57-51-37-000-002-A | Removal of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB) |
Subtask 29-13-53-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(3) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the Yellow hydraulic system.
(4) Put a WARNING NOTICE(S) in position to tell persons not to operate the flap/slat controls.
Subtask 29-13-53-860-050-A ** ON A/C NOT FOR ALL WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
(1) Obey the hydraulic safety procedures when you do work on the hydraulic system (Ref. AMM TASK 29-00-00-910-002). (2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(3) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the Yellow hydraulic system.
(4) Put a WARNING NOTICE(S) in position to tell persons not to operate the flap/slat controls.
B. Aircraft Maintenance Configuration
(1) Extend the flaps for access (Ref. AMM TASK 27-50-00-866-008).
(2) Install the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION on the flap/slat control lever (Ref. AMM TASK 27-00-00-480-002).
(Ref. AMM TASK 29-10-00-864-002).
(4) Depressurize the reservoir of the Yellow hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(5) Disconnect the isolation coupling of the PTU (Ref. AMM TASK 29-23-00-860-001).
Subtask 29-13-53-865-050-A ** ON A/C NOT FOR ALL (1) Extend the flaps for access (Ref. AMM TASK 27-50-00-866-008).
(2) Install the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION on the flap/slat control lever (Ref. AMM TASK 27-00-00-480-002).
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(3) Depressurize the Yellow hydraulic system(Ref. AMM TASK 29-10-00-864-002).
(4) Depressurize the reservoir of the Yellow hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(5) Disconnect the isolation coupling of the PTU (Ref. AMM TASK 29-23-00-860-001).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 29-13-53-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYDRAULIC/G HYD/PUMP ENG1/CTL | 1701GK | H12 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R34 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/Y HYD/PUMP ENG2/CTL | 3701GD | Q36 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N31 |
| 121VU | HYDRAULIC/G HYD/PUMP ENG1/MONG | 1702GK | R33 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
D. Get Access
(1) Put an ACCESS PLATFORM 3M (10 FT) below the access panel 673CB.
(2) Remove the access panels 673CB and 673EB (Ref. AMM TASK 57-51-37-000-002).
(3) Put a Textile-Lint free Cotton - (Material No.14SBA1) below the damper (1).
(4) Put a CONTAINER 1 L (1/4 USGAL) below the access panel 673EB.
4. Procedure(1) Put an ACCESS PLATFORM 3M (10 FT) below the access panel 673CB.
(2) Remove the access panels 673CB and 673EB (Ref. AMM TASK 57-51-37-000-002).
(3) Put a Textile-Lint free Cotton - (Material No.14SBA1) below the damper (1).
(4) Put a CONTAINER 1 L (1/4 USGAL) below the access panel 673EB.
Subtask 29-13-53-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Damper
(2) Remove the damper (1) from the connector (3).
(3) Remove and discard the O-ring (2) (Ref. AMM TASK 20-29-00-911-002).
(4) Put the PLUG-BLANKING in each disconnected line end.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(1) Remove and discard the lockwire from the damper (1). (2) Remove the damper (1) from the connector (3).
(3) Remove and discard the O-ring (2) (Ref. AMM TASK 20-29-00-911-002).
(4) Put the PLUG-BLANKING in each disconnected line end.
Damper (3600GM) - Location and Detail