Installation of the Reservoir Drain Valve
TASK 29-12-35-400-001-A
Installation of the Reservoir Drain Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 29-12-35-860-051-A
Subtask 29-12-35-420-050-A
Subtask 29-12-35-942-050-A
[Rev.10 from 2021]
2026.04.01 07:53:18 UTC
Installation of the Reservoir Drain Valve
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
FIN: 2264GM
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | CONTAINER - HYDRAULIC FLUID RESISTANT |
| No specific | 2 | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 5.14 and 5.03 m.daN (37.91 and 37.09 lbf.ft ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.02ABA1) | Phosphate Ester Hydraulic Fluid-General Power - - |
| No specific | lockwire 0.8 mm (0.032 in.) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 197EB |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 2 | O-RING | AIPC 29-12-04-11-260 |
| 2 | O-RING | AIPC 29-12-84-08-420 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-12-29-611-001-A | Fill the Hydraulic Fluid Reservoir with a Hand Pump |
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 29-00-00-910-002-A | Safety Procedures of the Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 29-14-00-614-002-A | Pressurization of the Hydraulic Reservoirs through the Ground Connector |
| TASK 29-14-00-614-002-A-01 | Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU) |
Subtask 29-12-35-860-051-A
A. Aircraft Maintenance Configuration
(2) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
(3) Make sure that the reservoir of the Blue hydraulic system is depressurized.
(Ref. AMM TASK 29-14-00-614-001).
(4) Make sure that the access panel 197EB is open.
(5) Make sure that the CONTAINER - HYDRAULIC FLUID RESISTANT is in position.
(6) Make sure that the WARNING NOTICE(S) are in position to tell persons not to pressurize the Blue hydraulic system:
Subtask 29-12-35-865-051-A WARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
(1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002). (2) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
(3) Make sure that the reservoir of the Blue hydraulic system is depressurized.
(Ref. AMM TASK 29-14-00-614-001).
(4) Make sure that the access panel 197EB is open.
(5) Make sure that the CONTAINER - HYDRAULIC FLUID RESISTANT is in position.
(6) Make sure that the WARNING NOTICE(S) are in position to tell persons not to pressurize the Blue hydraulic system:
- in the cockpit on the hydraulic section 40VU of the overhead panel,
- on the ground service panel of the Blue hydraulic system.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | HYD/HYD PWR/B WARN/& CTL | 2702GJ | C12 |
| 123VU | B HYD/ELEC PUMP | 2701GJ | AB09 |
Subtask 29-12-35-420-050-A
A. Installation of the Reservoir Drain Valve
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the blanking plug from the adaptor (3).
(4) Remove the blanking plug or the blanking cap from the reservoir drain valve (1).
(5) Apply Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) to the threads of the adaptor (3) and to the AIPC 29-12-04-11-260 O-RING (2) or AIPC 29-12-84-08-420 O-RING (2).
(6) Install the reservoir drain valve (1).
(7) TORQUE the reservoir drain valve (1) to between 5.14 and 5.03 m.daN (37.91 and 37.09 lbf.ft )
.
(8) Safety the reservoir drain valve (1) with lockwire 0.8 mm (0.032 in.).
Subtask 29-12-35-790-050-A (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the blanking plug from the adaptor (3).
(4) Remove the blanking plug or the blanking cap from the reservoir drain valve (1).
(5) Apply Phosphate Ester Hydraulic Fluid-General Power - - (Material No.02ABA1) to the threads of the adaptor (3) and to the AIPC 29-12-04-11-260 O-RING (2) or AIPC 29-12-84-08-420 O-RING (2).
(6) Install the reservoir drain valve (1).
(7) TORQUE the reservoir drain valve (1) to between 5.14 and 5.03 m.daN (37.91 and 37.09 lbf.ft )
. (8) Safety the reservoir drain valve (1) with lockwire 0.8 mm (0.032 in.).
B. Test
(1) Pressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-002).
(2) Make sure that fluid level in the reservoir of the Blue hydraulic system is correct. Add fluid as necessary (Ref. AMM TASK 12-12-29-611-001).
(3) Make sure that there are no leaks from the connection of the reservoir drain valve (1) and the adapter (3).
5. Close-up(1) Pressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-002).
(2) Make sure that fluid level in the reservoir of the Blue hydraulic system is correct. Add fluid as necessary (Ref. AMM TASK 12-12-29-611-001).
(3) Make sure that there are no leaks from the connection of the reservoir drain valve (1) and the adapter (3).
Subtask 29-12-35-942-050-A
A. Put the aircraft back to the serviceable condition.
(1) Remove the container.
(2) Remove the warning notices from the cockpit and the ground service panel.
Subtask 29-12-35-410-050-A (1) Remove the container.
(2) Remove the warning notices from the cockpit and the ground service panel.
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 197EB.
Subtask 29-12-35-865-052-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 197EB.
Reservoir Drain Valve