Reactivation of the Spoiler Elevator Computer (SEC)
TASK 27-94-00-440-002-A
Reactivation of the Spoiler Elevator Computer (SEC)
1. Reason for the Job
MMEL 27-94-01A
SEC 1
MMEL 27-94-02A
SEC 2
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 27-94-00-860-058-A Subtask 27-94-00-010-054-A
Subtask 27-94-00-440-050-A
Subtask 27-94-00-410-052-A
[Rev.10 from 2021]
2026.03.31 23:59:36 UTC
Reactivation of the Spoiler Elevator Computer (SEC)
1. Reason for the Job
MMEL 27-94-01A
SEC 1
MMEL 27-94-02A
SEC 2
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 27-94-00-860-058-A Subtask 27-94-00-010-054-A
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 822.
(2) Open the access door 822.
(3) At the battery power center 105VU:
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 822.
(2) Open the access door 822.
(3) At the battery power center 105VU:
- Loosen the two screws and remove the protective cover.
Subtask 27-94-00-440-050-A
A. Reactivation of the Spoiler Elevator Computer (SEC)
(1) Remove the WARNING NOTICE(S).
(2) Close the circuit breaker(s) 21CE1 and 22CE (SEC1) or 21CE2 (SEC2) related to the SEC that you must activate.
(3) Do a trouble shooting of the reactivated SEC. Make the necessary corrections.
5. Close-up(1) Remove the WARNING NOTICE(S).
(2) Close the circuit breaker(s) 21CE1 and 22CE (SEC1) or 21CE2 (SEC2) related to the SEC that you must activate.
(3) Do a trouble shooting of the reactivated SEC. Make the necessary corrections.
Subtask 27-94-00-410-052-A
A. Close Access
(1) Install the protective cover on the battery power center 105VU.
(2) Tighten the two screws.
(3) Close the access door 822.
(4) Remove the access platform(s).
(5) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) Install the protective cover on the battery power center 105VU.
(2) Tighten the two screws.
(3) Close the access door 822.
(4) Remove the access platform(s).
(5) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).