Adjustment of the Lavatory Door
TASK 25-40-00-820-003-A
Adjustment of the Lavatory Door
Self explanatory
2. Job Set-up Information
A. Consumable Materials
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-40-00-861-059-A 4. Procedure
Subtask 25-40-00-820-054-A
Subtask 25-40-00-862-060-A
[Rev.10 from 2021]
2026.03.31 23:34:51 UTC
Adjustment of the Lavatory Door
ZONE: 200
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05BAE1) | Threadlocking Adhesive-- Medium strength - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 25-40-00-861-059-A 4. Procedure
Subtask 25-40-00-820-054-A
A. Adjustment of the Lavatory Single Blade Doors
(1) Open the lavatory door (6).
(2) Loosen the screws (4).
(3) Adjust the hinge (5) to get the dimension C clearance between the lavatory door (6) and the door frame.
(4) Tighten the screws (4).
(5) Close the lavatory door (6).
Subtask 25-40-00-820-053-A (1) Open the lavatory door (6).
(2) Loosen the screws (4).
(3) Adjust the hinge (5) to get the dimension C clearance between the lavatory door (6) and the door frame.
(4) Tighten the screws (4).
(5) Close the lavatory door (6).
B. Adjustment of the Lavatory Bi-folding Doors (Standard Option)
(1) Loosen the grubscrew (2).
(2) Adjust the nut (3) to get the dimension C clearance between the lavatory door (1) and the door frame.
(3) Tighten the grubscrew (2).
(4) Apply Threadlocking Adhesive-- Medium strength - (Material No.05BAE1) to the grubscrew (2).
5. Close-up(1) Loosen the grubscrew (2).
(2) Adjust the nut (3) to get the dimension C clearance between the lavatory door (1) and the door frame.
(3) Tighten the grubscrew (2).
(4) Apply Threadlocking Adhesive-- Medium strength - (Material No.05BAE1) to the grubscrew (2).
Subtask 25-40-00-862-060-A
Adjustment - Single-Blade Door