Operational Test of the Hot Plate
TASK 25-35-00-710-026-A
Operational Test of the Hot Plate
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 25-35-00-861-075-A ** ON A/C NOT FOR ALL Subtask 25-35-00-865-095-A ** ON A/C NOT FOR ALL
Subtask 25-35-00-710-077-A ** ON A/C NOT FOR ALL
5. Close-up
Subtask 25-35-00-410-064-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 06:16:16 UTC
Operational Test of the Hot Plate
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 25-35-00-861-075-A ** ON A/C NOT FOR ALL Subtask 25-35-00-865-095-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 25-35-00-860-064-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | ELEC/GALLEY/CNTOR | 7MC | S28 |
| 122VU | ELEC/GALY & CAB/CTL | 1XA | S26 |
| 123VU | FWD GALLEY/FEEDER F | 16MC | AC10 |
| 123VU | AFT GALLEY/FEEDER E | 14MC | AF09 |
| 123VU | AFT GALLEY/FEEDER A | 3MC | AF04 |
C. Aircraft Maintenance Configuration
(1) Make sure that the pushbutton GALLEY 2XA on the overhead panel 35VU is in the on position (the white OFF indicator does not come on).
(2) Make sure that the related C/B(s) of the hot-plate on the galley control panel is(are) closed.
4. Procedure(1) Make sure that the pushbutton GALLEY 2XA on the overhead panel 35VU is in the on position (the white OFF indicator does not come on).
(2) Make sure that the related C/B(s) of the hot-plate on the galley control panel is(are) closed.
Subtask 25-35-00-710-077-A ** ON A/C NOT FOR ALL
WARNING:
DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
A. Do the Operational Test of the Hot-Plate | ACTION | RESULT |
|---|---|
1.At the hot plate:
| At the hot plate:
|
|
|
Subtask 25-35-00-410-064-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Put all related C/B and switches to their initial configuration.
(2) Make sure that the hot-plate is in its initial configuration.
(3) Make sure that the work area is clean and clear of tools and other items.
Subtask 25-35-00-862-075-A ** ON A/C NOT FOR ALL (1) Put all related C/B and switches to their initial configuration.
(2) Make sure that the hot-plate is in its initial configuration.
(3) Make sure that the work area is clean and clear of tools and other items.