W DOC AIRBUS | AMM A320F

Operational Test of the Hot Plate


TASK 25-35-00-710-026-A
Operational Test of the Hot Plate


1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 25-35-00-861-075-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 25-35-00-865-095-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUELEC/GALLEY/CNTOR7MCS28
122VUELEC/GALY & CAB/CTL1XAS26
123VUFWD GALLEY/FEEDER F16MCAC10
123VUAFT GALLEY/FEEDER E14MCAF09
123VUAFT GALLEY/FEEDER A3MCAF04
Subtask 25-35-00-860-064-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Make sure that the pushbutton GALLEY 2XA on the overhead panel 35VU is in the on position (the white OFF indicator does not come on).
   (2) Make sure that the related C/B(s) of the hot-plate on the galley control panel is(are) closed.
4. Procedure
Subtask 25-35-00-710-077-A ** ON A/C NOT FOR ALL
WARNING: DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
A. Do the Operational Test of the Hot-Plate
ACTION
RESULT
1.At the hot plate:
  • Set the turnbutton to the unlocked position and pull the hot-plate fully out with the handle.
At the hot plate:
  • The hot plate comes on automatically. The heating element becomes hot.
  • Move the hot-plate with the handle fully in and set the turnbutton to the locked position.
  • The hot-plate goes off automatically.
5. Close-up
Subtask 25-35-00-410-064-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Put all related C/B and switches to their initial configuration.
   (2) Make sure that the hot-plate is in its initial configuration.
   (3) Make sure that the work area is clean and clear of tools and other items.
Subtask 25-35-00-862-075-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.03.31 23:34:20 UTC