Reactivation of the Crew Foot Warmers (FAA Operators Only)
TASK 25-15-00-440-801-A
Reactivation of the Crew Foot Warmers (FAA Operators Only)
MMEL 25-15-01
CREW FOOT WARMERS (FAA ONLY)
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 25-15-00-860-052-A ** ON A/C NOT FOR ALL
Subtask 25-15-00-440-050-A ** ON A/C NOT FOR ALL
Subtask 25-15-00-860-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:29:27 UTC
Reactivation of the Crew Foot Warmers (FAA Operators Only)
ZONE: 211
ZONE: 212
FIN: 2DR1 ** ON A/C NOT FOR ALL
FIN: 2DR2 ** ON A/C NOT FOR ALL
FIN: 2DR3 ** ON A/C NOT FOR ALL
FIN: 2DR4 ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 212
FIN: 2DR1 ** ON A/C NOT FOR ALL
FIN: 2DR2 ** ON A/C NOT FOR ALL
FIN: 2DR3 ** ON A/C NOT FOR ALL
FIN: 2DR4 ** ON A/C NOT FOR ALL
MMEL 25-15-01
CREW FOOT WARMERS (FAA ONLY)
NOTE: The reactivation of the crew foot warmers is applicable only to the FAA operators.
2. Job Set-up InformationA. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 212 | COCKPIT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 25-15-00-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
Subtask 25-15-00-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | FOOT WARMER | 1DR | X15 |
Subtask 25-15-00-440-050-A ** ON A/C NOT FOR ALL
A. Reactivation of the Crew Foot Warmers
(1) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 25-15-00-710-050-A ** ON A/C NOT FOR ALL (1) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
- [1DR] .
B. Operational Test
Do the operational test of the foot warmer as follows:
(a) On CAPT LIGHTING/LOUDSPEAKER control-panel 301VU, set the FOOT WARMER control switch (3DR1) to the ON position.
(b) Make sure that the foot warmer operates.
(c) On CAPT LIGHTING/LOUDSPEAKER control-panel 301VU, set the FOOT WARMER control switch (3DR1) to the OFF position.
(2) FOR [2DR2] (WARMER-FOOT, F/O R), [2DR4] (WARMER-FOOT, F/O L)
Do the operational test of the foot warmer as follows:
(a) On F/O LIGHTING/LOUDSPEAKER control-panel 500VU, set the FOOT WARMER control switch (3DR2) to the ON position.
(b) Make sure that the foot warmer operates.
(c) On F/O LIGHTING/LOUDSPEAKER control-panel 500VU, set the FOOT WARMER control switch (3DR2) to the OFF position.
5. Close-upNOTE: Do this test only if a handset is installed.
(1) FOR [2DR1] (WARMER-FOOT, CAPT R), [2DR3] (WARMER-FOOT, CAPT L)Do the operational test of the foot warmer as follows:
(a) On CAPT LIGHTING/LOUDSPEAKER control-panel 301VU, set the FOOT WARMER control switch (3DR1) to the ON position.
(b) Make sure that the foot warmer operates.
(c) On CAPT LIGHTING/LOUDSPEAKER control-panel 301VU, set the FOOT WARMER control switch (3DR1) to the OFF position.
(2) FOR [2DR2] (WARMER-FOOT, F/O R), [2DR4] (WARMER-FOOT, F/O L)
Do the operational test of the foot warmer as follows:
(a) On F/O LIGHTING/LOUDSPEAKER control-panel 500VU, set the FOOT WARMER control switch (3DR2) to the ON position.
(b) Make sure that the foot warmer operates.
(c) On F/O LIGHTING/LOUDSPEAKER control-panel 500VU, set the FOOT WARMER control switch (3DR2) to the OFF position.
Subtask 25-15-00-860-053-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(2) Make sure that the work area is clean and clear of tools and other items.
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(2) Make sure that the work area is clean and clear of tools and other items.