General Visual Inspection of 90, 108, 109 VU in the Forward Avionic Compartment (EWIS)
TASK 24-92-00-210-028-A
General Visual Inspection of 90, 108, 109 VU in the Forward Avionic Compartment (EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200121-03
GENERAL VISUAL INSPECTION OF 90, 108, 109 VU IN THE FORWARD AVIONIC COMPARTMENT (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-92-00-010-090-A
Subtask 24-92-00-210-078-A
Subtask 24-92-00-410-088-A
[Rev.10 from 2021]
2026.03.31 23:26:07 UTC
General Visual Inspection of 90, 108, 109 VU in the Forward Avionic Compartment (EWIS)
1. Reason for the Job
Refer to the MPD TASK: 200121-03
GENERAL VISUAL INSPECTION OF 90, 108, 109 VU IN THE FORWARD AVIONIC COMPARTMENT (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | FLASHLIGHT |
| No specific | AR | MIRROR - INSPECTION, FLEXIBLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121 | AVIONICS COMPARTMENT |
| 122 | AVIONICS COMPARTMENT |
| 121AL, 811, 812, 822 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
| ESPM 2052110 | |
Subtask 24-92-00-010-090-A
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the applicable access door.
(2) Open these access doors:
Subtask 24-92-00-862-078-A (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the applicable access door.
(2) Open these access doors:
- 121AL
- 811, 812 and 822 (Ref. AMM TASK 52-41-00-010-002).
B. Make sure that the aircraft electrical circuits are de-energized
(Ref. AMM TASK 24-41-00-862-002).
4. Procedure(Ref. AMM TASK 24-41-00-862-002).
Subtask 24-92-00-210-078-A
A. General Visual Inspection of 90VU, 108VU and 109VU in the Forward Avionic Compartment
(1) Do a visual inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation ESPM 2052110:
(a) On the AC/DC feeder routes: 4G, 5G and 6G.
(b) On the AC/DC power-distribution routes: 1P, 2P and 6P.
(c) On the flight control wiring.
(d) On the engine control routes: 1S and 2S.
(e) On the other routes: 1M and 2M.
(f) On the audio route: 1R.
(g) On the coaxial cable routes: 4T, 3U and 4U.
(h) On the generator excitation routes: 1E, 2E and 3E.
5. Close-up(1) Do a visual inspection of the wiring to make sure that there is no signs of ageing, alteration, overheating, scaling and deformation ESPM 2052110:
(a) On the AC/DC feeder routes: 4G, 5G and 6G.
(b) On the AC/DC power-distribution routes: 1P, 2P and 6P.
(c) On the flight control wiring.
(d) On the engine control routes: 1S and 2S.
(e) On the other routes: 1M and 2M.
(f) On the audio route: 1R.
(g) On the coaxial cable routes: 4T, 3U and 4U.
(h) On the generator excitation routes: 1E, 2E and 3E.
NOTE: Use a FLASHLIGHT or a MIRROR - INSPECTION, FLEXIBLE if necessary.
(2) Make sure that there is no dust, lint or hydraulic contamination. Subtask 24-92-00-410-088-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close these access doors:
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close these access doors:
- 121AL
- 811, 812 and 822 (Ref. AMM TASK 52-41-00-410-002).
90VU, 108VU and 109VU Location