Apply Temporary Protection to End Fittings of Electrical Conduits in Main Landing Gear Bay and False Spar Box
TASK 24-92-00-210-014-A
Apply Temporary Protection to End Fittings of Electrical Conduits in Main Landing Gear Bay and False Spar Box
Refer to the MPD TASK: 240000-06
APPLY TEMPORARY PROTECTION TO END FITTINGS OF ELECTRICAL CONDUITS IN MAIN LANDING GEAR BAY AND FALSE SPAR BOX
Apply temporary protection to end fittings of electrical conduits in the MLG well and false spar box.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 24-92-00-862-064-A Subtask 24-92-00-869-079-A Subtask 24-92-00-010-064-A ** ON A/C NOT FOR ALL
Subtask 24-92-00-210-064-A
Subtask 24-92-00-410-065-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:25:50 UTC
Apply Temporary Protection to End Fittings of Electrical Conduits in Main Landing Gear Bay and False Spar Box
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT YOU OBEY ALL THE WARNINGS AND THE CAUTIONS INCLUDED IN THE REFERENCED PROCEDURES.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 240000-06
APPLY TEMPORARY PROTECTION TO END FITTINGS OF ELECTRICAL CONDUITS IN MAIN LANDING GEAR BAY AND FALSE SPAR BOX
Apply temporary protection to end fittings of electrical conduits in the MLG well and false spar box.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | BRUSH - BRISTLED |
| No specific | AR | SPRAY - BOTTLE, PUMP TYPE (NON AEROSOL) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.12ACB1) | Corrosion Preventive Compound-Heavy Duty Hard Film - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 571 | MLG BAY |
| 574 | FALSE SPAR BOX |
| 671 | MLG BAY |
| 674 | FALSE SPAR BOX |
| 574AB, 574BB, 674AB, 674BB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-34-24-869-002-A | Aircraft Grounding (Earthing) for the Maintenance Operations |
| TASK 12-34-24-869-002-A-01 | Aircraft Grounding (Earthing) during Transit, Turnaround or Overnight Stop |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 57-51-37-000-008-A | Removal of the Access Door |
| TASK 57-51-37-000-009-A | Removal of the Access Door |
| TASK 57-51-37-400-008-A | Installation of the Access Door |
| TASK 57-51-37-400-009-A | Installation of the Access Door |
| TASK 57-51-42-000-001-A | Removal of the Overwing Panel Protection |
| TASK 57-51-42-400-001-A | Installation of the Overwing Panel Protection |
| ESPM 203330 | |
Subtask 24-92-00-862-064-A Subtask 24-92-00-869-079-A Subtask 24-92-00-010-064-A ** ON A/C NOT FOR ALL
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the MLG well and false spar box.
(2) Remove and retain the access panels:
Subtask 24-92-00-010-064-C ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the MLG well and false spar box.
(2) Remove and retain the access panels:
- For the left wing:
- 574AB (Ref. AMM TASK 57-51-37-000-008)
- 574BB (Ref. AMM TASK 57-51-37-000-009).
- For the right wing:
- 674AB (Ref. AMM TASK 57-51-37-000-008)
- 674BB (Ref. AMM TASK 57-51-37-000-009).
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the MLG well and false spar box.
(2) Remove and retain the access panels:
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the MLG well and false spar box.
(2) Remove and retain the access panels:
- For the left wing:
- 574AB (Ref. AMM TASK 57-51-37-000-008)
- 574BB (Ref. AMM TASK 57-51-37-000-009).
- For the right wing:
- 674AB (Ref. AMM TASK 57-51-37-000-008)
- 674BB (Ref. AMM TASK 57-51-37-000-009).
Subtask 24-92-00-210-064-A
A. Temporary Protection of the Electrical Conduits End-Fittings in the Main Landing Gear Bay and the False Spar Box
(a) Use Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) to remove any contamination from the fitting.
(b) Remove flakes or blisters.
(d) Use a BRUSH - BRISTLED or an SPRAY - BOTTLE, PUMP TYPE (NON AEROSOL) to apply a continuous thin and smooth coat of Corrosion Preventive Compound-Heavy Duty Hard Film - (Material No.12ACB1) , to cover all the fitting ESPM 203330.
5. Close-upWARNING:
BE CAREFUL NOT TO CUT YOUR FINGERS. FLAKES OF NICKEL ARE SHARP.
(1) At each fitting use the procedure that follows to protect against corrosion: (a) Use Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) to remove any contamination from the fitting.
(b) Remove flakes or blisters.
NOTE: We recommend that you use a dental tool or a seal tool (non metallic) to remove the flakes and the blisters.
(c) During this task, make sure that the base metal is not damaged.(d) Use a BRUSH - BRISTLED or an SPRAY - BOTTLE, PUMP TYPE (NON AEROSOL) to apply a continuous thin and smooth coat of Corrosion Preventive Compound-Heavy Duty Hard Film - (Material No.12ACB1) , to cover all the fitting ESPM 203330.
Subtask 24-92-00-410-065-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panels:
(4) Remove the access platform(s).
Subtask 24-92-00-410-065-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panels:
- For the left wing:
- 574AB (Ref. AMM TASK 57-51-37-400-008)
- 574BB (Ref. AMM TASK 57-51-37-400-009).
- For the right wing:
- 674AB (Ref. AMM TASK 57-51-37-400-008)
- 674BB (Ref. AMM TASK 57-51-37-400-009).
(4) Remove the access platform(s).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the overwing panel protection, if removed (Ref. AMM TASK 57-51-42-400-001).
(3) Install the access panels:
(5) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the overwing panel protection, if removed (Ref. AMM TASK 57-51-42-400-001).
(3) Install the access panels:
- For the left wing:
- 574AB (Ref. AMM TASK 57-51-37-400-008)
- 574BB (Ref. AMM TASK 57-51-37-400-009).
- For the right wing:
- 674AB (Ref. AMM TASK 57-51-37-400-008)
- 674BB (Ref. AMM TASK 57-51-37-400-009).
(5) Remove the access platform(s).
Electrical Harness Conduits - Corrosion Protection