Operational Test of the GEN FAULT Warning
TASK 24-27-00-710-001-A
Operational Test of the GEN FAULT Warning
1. Reason for the Job
Make sure that the GEN FAULT warning is operative when there are no more indications on the ECAM ELEC page.
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 24-27-00-860-050-A
Subtask 24-27-00-710-050-A
Subtask 24-27-00-862-050-A
[Rev.10 from 2021]
2026.03.31 23:22:56 UTC
Operational Test of the GEN FAULT Warning
1. Reason for the Job
Make sure that the GEN FAULT warning is operative when there are no more indications on the ECAM ELEC page.
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 24-27-00-860-050-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) In the cockpit, on the overhead panel 35VU, make sure that the GEN1 (2) pushbutton switch is released.
4. Procedure(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) In the cockpit, on the overhead panel 35VU, make sure that the GEN1 (2) pushbutton switch is released.
Subtask 24-27-00-710-050-A
A. Operational Test of the GEN FAULT Warning:
5. Close-up| ACTION | RESULT |
|---|---|
1.On the panel 35VU:
| On the panel 35VU:
|
2.On the panel 35VU:
| On the panel 35VU:
|
Subtask 24-27-00-862-050-A