Operational Test of the Anti-Hijack Camera-Monitoring-System
TASK 23-72-00-710-001-A
Operational Test of the Anti-Hijack Camera-Monitoring-System
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 23-72-00-861-051-A ** ON A/C NOT FOR ALL Subtask 23-72-00-865-053-A ** ON A/C NOT FOR ALL
Subtask 23-72-00-710-051-C ** ON A/C NOT FOR ALL
Subtask 23-72-00-862-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 05:30:38 UTC
Operational Test of the Anti-Hijack Camera-Monitoring-System
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 220 | FWD CAB UTILITY AREAS |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 23-72-00-861-051-A ** ON A/C NOT FOR ALL Subtask 23-72-00-865-053-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 23-72-00-860-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | DOORS/PAX/MONG | 1MQ | T13 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | DOORS/CKPT/VIDEO/SPLY | 15RA | T16 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | DOORS CKPT LOCK | 1MQ | T13 |
C. Prepare the System Display (SD) for the test.
(1) On the Electronic Centralized Aircraft Monitoring (ECAM) control panel:
4. Procedure(1) On the Electronic Centralized Aircraft Monitoring (ECAM) control panel:
- Make sure that the LOWER DISPLAY potentiometer is between the OFF and BRT positions.
- Make sure that the system page keys are off.
- Push the CLR key until there are no system pages shown on the SD.
Subtask 23-72-00-710-051-C ** ON A/C NOT FOR ALL
A. Operational Test of the Anti-Hijack Camera-Monitoring-System
Subtask 23-72-00-710-051-D ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| 1.In the cockpit, on panel 27VU: | In the cockpit: |
|
|
| | In the cockpit, on the LCD monitor: |
| |
|
| 2.In the cockpit, on the panel 119VU: | In the cockpit, on the LCD monitor: |
|
|
| 3.In the cockpit, on the panel 119VU: | In the cockpit, on the LCD monitor: |
|
NOTE: The black screen is only shown if the LCD monitor has been programmed for the 'not-installed' fourth camera. |
| 4.In the cockpit, on the panel 119VU: | In the cockpit, on the LCD monitor: |
|
|
| 5.In the cockpit, on the LCD monitor: | In the cockpit, on the LCD monitor: |
|
|
| 6.In the cockpit, on the LCD monitor: | In the cockpit, on the LCD monitor: |
|
|
| 7.In the cockpit, on the panel 119VU: | In the cockpit, on the LCD monitor: |
|
NOTE: If the LCD monitor is not programmed for the power-down-mode then the images stay on. NOTE: If the LCD monitor has been programmed for the 'not-installed' fourth camera (black screen), the images go off after one minute. |
| 8.In the cockpit, on the panel 119VU: | In the cockpit, on the LCD monitor: |
|
|
| 9.In the cockpit entrance area, on the CDLS keypad: | In the cockpit: |
|
|
| | In the cockpit, on the LCD monitor: |
| |
|
NOTE: The next two steps must be done in less than 30 seconds after this step. | |
| 10.In the cockpit, on the panel 119VU: | In the cockpit, on the LCD monitor: |
|
|
| 11.In the cockpit entrance area, on the CDLS keypad: | In the cockpit: |
|
|
| 12.In the cockpit, on the panel 119VU: | In the cockpit, on the LCD monitor: |
|
|
| 13.In the cockpit, on the panel 119VU: | In the cockpit, on the LCD monitor: |
|
|
| 14.In the cockpit, on the panel 119VU: | In the cockpit, on the LCD monitor: |
|
NOTE: If the LCD monitor is not programmed for the pilot-sleep-mode then the LCD monitor displays camera 1. |
| 15.In the cockpit, on the panel 119VU: | In the cockpit, on the LCD monitor: |
|
|
| 16.In the cockpit, on the panel 119VU: | In the cockpit, on the LCD monitor: |
|
|
| 17.In the cockpit, on panel 27VU: | In the cockpit: |
|
|
| | In the cockpit, on the LCD monitor: |
| |
|
A. Operational Test of the Anti-Hijack Camera-Monitoring-System
5. Close-up| ACTION | RESULT |
|---|---|
| 1.On the panel 27VU in the cockpit: | On the panel 27VU in the cockpit: |
|
|
| 2.On the panel 119VU in the cockpit: | On the System Display (SD): |
|
|
|
|
| 3.On the Cockpit-Door Lock-System (CDLS) keypad in the cockpit entrance area: | In the cockpit: |
|
|
| | On the SD: |
| |
|
| 4.You must do the step 5 and start the step 6 in less than 30 seconds after the step 3. | |
| 5.On the panel 119VU in the cockpit: | On the SD: |
|
|
| 6.On the CDLS keypad in the cockpit entrance area: | In the cockpit: |
|
|
| | On the SD: |
| |
|
| After 30 seconds: | In the cockpit: |
NOTE: This step can be not necessary because the last entry code can be kept by the CDSS controller and will be automatically applied after 30 seconds. |
|
| | On the SD: |
| |
|
|
|
| | On the SD: |
| |
|
| 7.On the panel 119VU in the cockpit: | On the SD: |
|
|
| 8.On the panel 8VU: | On the SD: |
|
|
| 9.In the forward entrance area: | In the forward entrance area: |
|
|
| 10.On the Flight Attendant Panel (FAP): | In the forward entrance area: |
|
|
| 11.On the panel 119VU in the cockpit: | On the SD: |
|
|
|
|
| 12.On the panel 27VU in the cockpit: | On the panel 27VU in the cockpit: |
|
|
Subtask 23-72-00-862-051-A ** ON A/C NOT FOR ALL