W DOC AIRBUS | AMM A320F

Operational Test of the Radio Management Panel (RMP)


TASK 23-13-00-710-001-A
Operational Test of the Radio Management Panel (RMP)


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
NOTE: You can do this test in the hangar.
ZONE: 210
1. Reason for the Job
To do a check of the dialog between the Radio Management Panels (RMPs).
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 23-13-00-861-050-A
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002)
Subtask 23-13-00-865-050-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUCOM/RMP/12RG1G10
49VUCOM/VHF/12RC1G09
121VUCOM NAV/RMP/22RG2L02
** ON A/C NOT FOR ALL
121VUCOM NAV/RMP/32RG3L03
4. Procedure
Subtask 23-13-00-710-050-A ** ON A/C NOT FOR ALL
A. Operational Test of the Radio Management
ACTION
RESULT
1.On the RMP1:

  • Set the ON/OFF selector switch to ON.
  • The RMP shows the last frequencies and the last function used.
  • Push the VHF1 pushbutton switch.
  • The green LED on this pushbutton switch comes on.

  • In the STBY/CRS display window, with the dual selector knob, set the frequency of a station that transmits.


  • Start this frequency. To do this, push the transfer pushbutton switch (double arrow) between the two windows.
  • In the ACTIVE display window, the frequency set comes into view.

2.On the RMP2:

  • Set the ON/OFF selector switch to ON.
  • The RMP shows the last frequencies and the last function used.

  • Push the VHF1 pushbutton switch.
  • The ACTIVE display window shows the same frequencies as the RMP1.
  • The green LED on this pushbutton switch comes on.

    On the RMP1 and the RMP2:
  • The SEL indicator light (amber LED) is on.

  • In the STBY/CRS display window, set a new frequency with the dual selector knob.


  • Start this frequency. To do this, push the transfer pushbutton switch (double arrow) between the two windows.
  • In the ACTIVE display window, the frequency set comes into view.
Subtask 23-13-00-710-050-B ** ON A/C NOT FOR ALL
A. Operational Test of the Radio Management
ACTION
RESULT
1.On the RMP1:
  • Set the ON/OFF switch to ON.
The RMP1 shows the last frequencies and the last function used.
2.On the RMP1:
  • Push the VHF1 pushbutton switch.
On the RMP1:
  • The green LED on the VHF1 pushbutton switch comes on (it does not come on if the last function used was the VHF1 function).
3.On the RMP1:
  • In the right window, with the dual selector knob, set the frequency of a station that transmits.

4.On the RMP1:
  • Start the frequency set. To do this, push the pushbutton switch (double arrow) between the two windows.
On the RMP1:
  • In the left window, the frequency set comes into view.
5.On the RMP2 and the RMP3:
  • Set the ON/OFF switch to ON.
The RMP2 and 3 show the last frequencies and the last functions used.
6.On the RMP2 and the RMP3:
  • Push the VHF1 pushbutton switch.
On the RMP2 and the RMP3:
  • The left window shows the same frequency as the RMP1
  • The green LED on the VHF1 pushbutton switch comes on.
    On the RMP1, the RMP2 and the RMP3:
  • The SEL indicator light (amber LED) is on.
7.On the RMP2:
  • In the right window, set a new frequency with the dual selector knob.

8.On the RMP2:
  • Start the frequency set. To do this, push the pushbutton switch (double arrow) between the two windows.
On the RMP2:
  • In the left window, the frequency set comes into view.
    On the RMP1 and the RMP3:
  • The left window shows the same frequency as on the RMP2.
9.On the RMP3:
  • In the right window, set a new frequency with the dual selector knob.

10.On the RMP3:
  • Start the frequency set. To do this, push the pushbutton switch (double arrow) between the two windows.
On the RMP3:
  • In the left window, the frequency set comes into view.
    On the RMP1 and the RMP2:
  • The left window shows the same frequency as on the RMP3.
5. Close-up
Subtask 23-13-00-860-050-A
A. Put the aircraft back to its initial configuration.
   (1) On the RMPs, set the ON/OFF selector switch to OFF.
   (2) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.03.31 23:12:27 UTC