W DOC AIRBUS | AMM A320F

Operational Test of the Indicator Lights and Displays of the FCU


TASK 22-10-00-710-005-A
Operational Test of the Indicator Lights and Displays of the FCU


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
ZONE: 210
1. Reason for the Job
To do a check of the indicator lights and displays of the FCU.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 22-10-00-861-054-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 22-10-00-865-054-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAUTO FLT/FCU/19CA1B05
49VUAUTO FLT/FMGC/110CA1B02
** ON A/C NOT FOR ALL
49VUAUTO FLT/FCU/19CA1H11
49VUAUTO FLT/FMGC/110CA1H08
** ON A/C ALL
121VUAUTO FLT/FCU/29CA2M21
121VUAUTO FLT/FMGC/210CA2M17
122VULIGHTING/TST/BOARD/SPLY30LPX06
4. Procedure
Subtask 22-10-00-710-055-B
A. Do this test:
ACTION
RESULT
1.On the overhead panel, on the panel 25VU:
  • Make sure that the ANN LT switch is set to DIM.

2.On the panel 25VU:
  • Set the ANN LT switch to TEST.
On the FCU:
  • The 3 green bars on the pushbutton switches come on.
  • All the segments in the display windows and the three associated green indicator lights come on.
3.Set the ANN LT switch to DIM.
You must get the same result as in
step 1.
5. Close-up
Subtask 22-10-00-862-054-A
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.03.31 23:09:53 UTC