W DOC AIRBUS | AMM A320F

Operational Test of the FCU Lighting


TASK 22-10-00-710-004-A
Operational Test of the FCU Lighting


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
ZONE: 210
1. Reason for the Job
To do a check of the integral lighting and the window lighting of the FCU.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 22-10-00-861-053-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 22-10-00-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAUTO FLT/FCU/19CA1B05
** ON A/C NOT FOR ALL
49VUAUTO FLT/FCU/19CA1H11
** ON A/C ALL
121VUAUTO FLT/FCU/29CA2M21
122VULIGHTING/INSTL LT/GLARE/SHLD5LFY05
4. Procedure
Subtask 22-10-00-710-054-A
A. Do this test:
ACTION
RESULT
1.On the glareshield, below the FCU:
On the FCU:
Set the two potentiometers to their left stop.
  • On the front face, the indications go off.
  • The window lighting goes off.
2.Set the left potentiometer to the right stop.
  • All the indications on the front face get brighter.
3.Set the right potentiometer to the right stop.
  • The window lighting increases.
4.Set the two potentiometers to the left stop.
  • Same result as in step 1.
5. Close-up
Subtask 22-10-00-862-053-A
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.03.31 23:09:52 UTC