Cleaning of the Moveable Seals of the Outflow-Valve
TASK 21-31-00-100-001-A
Cleaning of the Moveable Seals of the Outflow-Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 21-31-00-861-065-A Subtask 21-31-00-865-068-A
Subtask 21-31-00-110-050-A ** ON A/C NOT FOR ALL
Subtask 21-31-00-860-070-A
[Rev.10 from 2021]
2026.03.31 23:04:38 UTC
Cleaning of the Moveable Seals of the Outflow-Valve
WARNING:
MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
MAKE SURE THAT THE FWD AVIONICS ACCESS DOOR 811 IS OPEN WITH A WARNING PLACARD ATTACHED TO IT.
THE WARNING NOTICE MUST TELL PERSONS NOT TO CLOSE THE DOOR. THIS PREVENTS ACCIDENTAL PRESSURIZATION OF THE AIRCRAFT.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | AIR SOURCE 0 TO 1 BAR (0 TO 15 PSI) |
| No specific | AR | BRUSH - BRISTLED, SOFT |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BBE1) | Non Aqueous Cleaner-- Methyl Alcohol - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-31-51-000-001-A | Removal of the Outflow Valve (From Inside) |
| TASK 21-31-51-000-006-A | Removal of the Outflow Valve (From Outside) |
| TASK 21-31-51-400-001-A | Installation of the Outflow Valve (From Inside) |
| TASK 21-31-51-400-006-A | Installation of the Outflow Valve (From Outside) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 21-31-00-861-065-A Subtask 21-31-00-865-068-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 21-31-00-941-054-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR COND/CAB/PRESS/CTL1 | 1HL | D09 |
| 122VU | AIR COND/CAB PRESS/CTL/MAN | 3HL | Y23 |
| 122VU | AIR COND/CAB PRESS/CTL/2 | 2HL | Y22 |
C. Put the ACCESS PLATFORM 2M (6 FT) in position below the outflow valve in zone 172.
Subtask 21-31-00-860-069-A D. Make sure that the outflow valve is in the open position.
4. ProcedureSubtask 21-31-00-110-050-A ** ON A/C NOT FOR ALL
A. Cleaning of the Outflow-Valve Moveable Seals
(2) Blow any dust or loose deposits from the moveable seals with a AIR SOURCE 0 TO 1 BAR (0 TO 15 PSI).
(3) If necessary repeat the cleaning procedure until the seals move freely with a light finger pressure.
(4) If the seals are clean:
(a) Press them into their slots with two fingers.
If the seals do not come out easily and smoothly:
(b) Remove the related outflow valve (Ref. AMM TASK 21-31-51-000-001) or (Ref. AMM TASK 21-31-51-000-006)
(c) Replace the springs (2) as follows:
Subtask 21-31-00-110-050-B ** ON A/C NOT FOR ALL WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
(1) Clean the moveable seals (1) with a BRUSH - BRISTLED, SOFT, Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-- Methyl Alcohol - (Material No.08BBE1) . (2) Blow any dust or loose deposits from the moveable seals with a AIR SOURCE 0 TO 1 BAR (0 TO 15 PSI).
(3) If necessary repeat the cleaning procedure until the seals move freely with a light finger pressure.
(4) If the seals are clean:
(a) Press them into their slots with two fingers.
If the seals do not come out easily and smoothly:
(b) Remove the related outflow valve (Ref. AMM TASK 21-31-51-000-001) or (Ref. AMM TASK 21-31-51-000-006)
(c) Replace the springs (2) as follows:
- Remove the screws (4)
- Lift the seals (3), (5), (6), (7), (8) and (9) and remove the springs (2)
- Install new springs (2)
- Put the seals (3), (5), (6), (7), (8) and (9) in position
- Install the screws (4).
NOTE: Seals must slide freely after installation of screw.
(d) Install the related outflow valve (Ref. AMM TASK 21-31-51-400-001) or (Ref. AMM TASK 21-31-51-400-006)A. Cleaning of the Outflow-Valve Moveable Seals
(2) Blow any dust or loose deposits from the moveable seals with a AIR SOURCE 0 TO 1 BAR (0 TO 15 PSI).
(3) If necessary repeat the cleaning procedure until the seals move freely with a light finger pressure.
(4) If the seals are clean:
(a) Press them into their slots with two fingers.
If the seals do not come out easily and smoothly:
(b) Remove the related outflow valve (Ref. AMM TASK 21-31-51-000-001)
(c) Replace the springs (2) as follows:
5. Close-upWARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
(1) Clean the moveable seals (1) with a BRUSH - BRISTLED, SOFT, Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-- Methyl Alcohol - (Material No.08BBE1) . (2) Blow any dust or loose deposits from the moveable seals with a AIR SOURCE 0 TO 1 BAR (0 TO 15 PSI).
(3) If necessary repeat the cleaning procedure until the seals move freely with a light finger pressure.
(4) If the seals are clean:
(a) Press them into their slots with two fingers.
If the seals do not come out easily and smoothly:
(b) Remove the related outflow valve (Ref. AMM TASK 21-31-51-000-001)
(c) Replace the springs (2) as follows:
- Remove the screws (4)
- Lift the seals (3), (5), (6), (7), (8) and (9) and remove the springs (2)
- Install new springs (2)
- Put the seals (3), (5), (6), (7), (8) and (9) in position
- Install the screws (4).
NOTE: Seals must slide freely after installation of screw.
(d) Install the related outflow valve (Ref. AMM TASK 21-31-51-400-001)Subtask 21-31-00-860-070-A
A. Aircraft Maintenance Configuration
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
Subtask 21-31-00-865-069-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 21-31-00-862-062-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR COND/CAB/PRESS/CTL1 | 1HL | D09 |
| 122VU | AIR COND/CAB PRESS/CTL/MAN | 3HL | Y23 |
| 122VU | AIR COND/CAB PRESS/CTL/2 | 2HL | Y22 |
Outflow-Valve Moveable Seals - Component Location