W DOC AIRBUS | AMM A320F

Cleaning of the Moveable Seals of the Outflow-Valve


TASK 21-31-00-100-001-A
Cleaning of the Moveable Seals of the Outflow-Valve


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: MAKE SURE THAT THE FWD AVIONICS ACCESS DOOR 811 IS OPEN WITH A WARNING PLACARD ATTACHED TO IT. THE WARNING NOTICE MUST TELL PERSONS NOT TO CLOSE THE DOOR. THIS PREVENTS ACCIDENTAL PRESSURIZATION OF THE AIRCRAFT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
AR
AIR SOURCE 0 TO 1 BAR (0 TO 15 PSI)
No specific
AR
BRUSH - BRISTLED, SOFT
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BBE1)
Non Aqueous Cleaner-- Methyl Alcohol -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 21-31-51-000-001-A
Removal of the Outflow Valve (From Inside)
TASK 21-31-51-000-006-A
Removal of the Outflow Valve (From Outside)
TASK 21-31-51-400-001-A
Installation of the Outflow Valve (From Inside)
TASK 21-31-51-400-006-A
Installation of the Outflow Valve (From Outside)
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 21-31-00-861-065-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 21-31-00-865-068-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAIR COND/CAB/PRESS/CTL11HLD09
122VUAIR COND/CAB PRESS/CTL/MAN3HLY23
122VUAIR COND/CAB PRESS/CTL/22HLY22
Subtask 21-31-00-941-054-A
C. Put the ACCESS PLATFORM 2M (6 FT) in position below the outflow valve in zone 172.
Subtask 21-31-00-860-069-A
D. Make sure that the outflow valve is in the open position.
4. Procedure
Subtask 21-31-00-110-050-A ** ON A/C NOT FOR ALL
A. Cleaning of the Outflow-Valve Moveable Seals
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
   (1) Clean the moveable seals (1) with a BRUSH - BRISTLED, SOFT, Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-- Methyl Alcohol - (Material No.08BBE1) .
   (2) Blow any dust or loose deposits from the moveable seals with a AIR SOURCE 0 TO 1 BAR (0 TO 15 PSI).
   (3) If necessary repeat the cleaning procedure until the seals move freely with a light finger pressure.
   (4) If the seals are clean:
     (a) Press them into their slots with two fingers.
If the seals do not come out easily and smoothly:
     (b) Remove the related outflow valve (Ref. AMM TASK 21-31-51-000-001) or (Ref. AMM TASK 21-31-51-000-006)
     (c) Replace the springs (2) as follows:
  • Remove the screws (4)
  • Lift the seals (3), (5), (6), (7), (8) and (9) and remove the springs (2)
  • Install new springs (2)
  • Put the seals (3), (5), (6), (7), (8) and (9) in position
  • Install the screws (4).
NOTE: Seals must slide freely after installation of screw.
     (d) Install the related outflow valve (Ref. AMM TASK 21-31-51-400-001) or (Ref. AMM TASK 21-31-51-400-006)
Subtask 21-31-00-110-050-B ** ON A/C NOT FOR ALL
A. Cleaning of the Outflow-Valve Moveable Seals
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
   (1) Clean the moveable seals (1) with a BRUSH - BRISTLED, SOFT, Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-- Methyl Alcohol - (Material No.08BBE1) .
   (2) Blow any dust or loose deposits from the moveable seals with a AIR SOURCE 0 TO 1 BAR (0 TO 15 PSI).
   (3) If necessary repeat the cleaning procedure until the seals move freely with a light finger pressure.
   (4) If the seals are clean:
     (a) Press them into their slots with two fingers.
If the seals do not come out easily and smoothly:
     (b) Remove the related outflow valve (Ref. AMM TASK 21-31-51-000-001)
     (c) Replace the springs (2) as follows:
  • Remove the screws (4)
  • Lift the seals (3), (5), (6), (7), (8) and (9) and remove the springs (2)
  • Install new springs (2)
  • Put the seals (3), (5), (6), (7), (8) and (9) in position
  • Install the screws (4).
NOTE: Seals must slide freely after installation of screw.
     (d) Install the related outflow valve (Ref. AMM TASK 21-31-51-400-001)
5. Close-up
Subtask 21-31-00-860-070-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
Subtask 21-31-00-865-069-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAIR COND/CAB/PRESS/CTL11HLD09
122VUAIR COND/CAB PRESS/CTL/MAN3HLY23
122VUAIR COND/CAB PRESS/CTL/22HLY22
Subtask 21-31-00-862-062-A
C. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.03.31 23:04:38 UTC