Operational Test of the Individual Air Outlet
TASK 21-21-00-710-002-A
Operational Test of the Individual Air Outlet
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 21-21-00-860-057-A
Subtask 21-21-00-710-053-A
Subtask 21-21-00-860-058-A
[Rev.10 from 2021]
2026.03.31 23:00:48 UTC
Operational Test of the Individual Air Outlet
WARNING:
MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 21-21-00-860-057-A
A. Aircraft Maintenance Configuration
(1) Energize the electrical circuits (Ref. AMM TASK 24-41-00-861-002)
Subtask 21-21-00-865-057-A (1) Energize the electrical circuits (Ref. AMM TASK 24-41-00-861-002)
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | AIR COND/RECIRC FAN/R/SPLY | 3HG | W18 |
| 122VU | AIR COND/RECIRC FAN/L/SPLY | 1HG | X18 |
Subtask 21-21-00-710-053-A
A. Do the operational test of the individual air outlet
(1) Open the applicable air outlet:
(a) Put your hand at the air outlet and make sure that you feel a continuous airflow.
(2) If there is no airflow:
(a) Make sure that the adjacent cabin air outlet gives sufficient airflow.
(b) Do a check of the air hose connections upstream of the air outlet.
(c) Do a check of the correct air hose installation.
(3) Close the applicable air outlet:
(a) Examine the fresh-air hose and the connections for leaks.
5. Close-up(1) Open the applicable air outlet:
(a) Put your hand at the air outlet and make sure that you feel a continuous airflow.
(2) If there is no airflow:
(a) Make sure that the adjacent cabin air outlet gives sufficient airflow.
(b) Do a check of the air hose connections upstream of the air outlet.
(c) Do a check of the correct air hose installation.
(3) Close the applicable air outlet:
(a) Examine the fresh-air hose and the connections for leaks.
NOTE: Leaks are not permitted.
Subtask 21-21-00-860-058-A
A. Put the aircraft back to its initial configuration.
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)