W DOC AIRBUS | AMM A320F

General Visual Inspection of Aileron (EWIS)


TASK 05-25-90-200-001-A
General Visual Inspection of Aileron (EWIS)


ZONE: 590
ZONE: 690
1. Reason for the Job
Refer to the MPD TASK: ZL-590-01
GENERAL VISUAL INSPECTION OF AILERON (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)
No specific
1
FLASHLIGHT
No specific
1
MIRROR - INSPECTION
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
590
AILERON
690
AILERON
590AB, 590BB, 690AB, 690BB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 57-51-37-000-011-A
Removal of the Access Panels
TASK 57-51-37-400-011-A
Installation of the Access Panels
3. Job Set-up
Subtask 05-25-90-861-050-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 05-25-90-010-050-A
B. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT) in position.
   (2) Remove access panels 590AB ( 690AB) and 590BB ( 690BB) (Ref. AMM TASK 57-51-37-000-011).
4. Procedure
Subtask 05-25-90-210-050-A
A. Inspection
   (1) If necessary, use the FLASHLIGHT and/or the MIRROR - INSPECTION.
   (2) Do a general visual inspection of the aileron.
   (3) Make sure that there are no signs of corrosion, cracks or damage.
   (4) Make sure that all the installations (wiring, ducting and piping) are correctly attached.
5. Close-up
Subtask 05-25-90-410-050-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install access panels 590AB ( 690AB) and 590BB ( 690BB) (Ref. AMM TASK 57-51-37-400-011).
   (3) Remove all the fixtures, tools, test and support equipment used during this procedure.
   (4) Remove the access platform(s).
Subtask 05-25-90-862-050-A
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.03.31 22:50:35 UTC