Installation of the Access Panels
TASK 57-51-37-400-011-A
Installation of the Access Panels
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 57-51-37-941-071-A
Subtask 57-51-37-210-050-A
Subtask 57-51-37-865-058-A
[Rev.10 from 2021]
2026.04.01 02:15:50 UTC
Installation of the Access Panels
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
CAUTION:
BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
1. Reason for the Job- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
- MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | Torque wrench: range to between 0.45 and 0.40 m.daN (39.82 and 35.40 lbf.in ) ![]() | |
| 98D27803500001 | 1 | LOCKING TOOL ZERO POS |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.06AAC1) | Polysulfide Sealant-General Purpose Interfay - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 57-51-37-941-071-A
A. Safety Precautions
(1) Make sure that the SAFETY BARRIER(S) are in position.
Subtask 57-51-37-860-066-A (1) Make sure that the SAFETY BARRIER(S) are in position.
B. Aircraft Maintenance Configuration
(1) Make sure that the 98D27803500001 LOCKING TOOL ZERO POS is installed on the flap/slat control lever.
(2) Make sure that the WARNING NOTICE(S) is in position in the cockpit to tell persons not to operate the flaps or slats.
Subtask 57-51-37-865-057-A (1) Make sure that the 98D27803500001 LOCKING TOOL ZERO POS is installed on the flap/slat control lever.
(2) Make sure that the WARNING NOTICE(S) is in position in the cockpit to tell persons not to operate the flaps or slats.
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 57-51-37-010-061-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B11 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B06 |
| ** ON A/C ALL | |||
| 105VU | FLIGHT CONTROLS/ELAC2/STBY SPLY | 16CE2 | A02 |
| 105VU | FLT CTL/ELAC1/STBY SPLY | 16CE1 | A01 |
| 121VU | FLIGHT CONTROLS/ELAC2/NORM/SPLY | 15CE2 | R20 |
D. Get Access
(1) Make sure that the ACCESS PLATFORM 4M (13 FT) is in position below the applicable access panel.
4. Procedure(1) Make sure that the ACCESS PLATFORM 4M (13 FT) is in position below the applicable access panel.
Subtask 57-51-37-210-050-A
A. Preparation for Installation
(1) Clean the component interfaces and/or the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the interface of the aircraft structure.
(4) Make sure that the parts retained from the removed component are clean and in the correct condition.
Subtask 57-51-37-420-067-A (1) Clean the component interfaces and/or the adjacent area with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) to the interface of the aircraft structure.
(4) Make sure that the parts retained from the removed component are clean and in the correct condition.
B. Installation of the Access Panels 590AB(690AB), 590BB(690BB)
(1) For the panel 590AB(690AB):
(a) Hold the access panel (1) in position and install the bolts (2).
(b) TORQUE the bolts (2) to between 0.45 and 0.40 m.daN (39.82 and 35.40 lbf.in )
.
(c) Make sure that the access panel (1) is correctly aligned with the adjacent panels.
(2) For the panel 590BB(690BB):
(a) Hold the access panel (3) in position and install the bolts (4).
(b) TORQUE the bolts (4) to between 0.45 and 0.40 m.daN (39.82 and 35.40 lbf.in )
.
(c) Make sure that the access panel (3) is correctly aligned with the adjacent panels.
5. Close-up(1) For the panel 590AB(690AB):
(a) Hold the access panel (1) in position and install the bolts (2).
(b) TORQUE the bolts (2) to between 0.45 and 0.40 m.daN (39.82 and 35.40 lbf.in )
. (c) Make sure that the access panel (1) is correctly aligned with the adjacent panels.
(2) For the panel 590BB(690BB):
(a) Hold the access panel (3) in position and install the bolts (4).
(b) TORQUE the bolts (4) to between 0.45 and 0.40 m.daN (39.82 and 35.40 lbf.in )
. (c) Make sure that the access panel (3) is correctly aligned with the adjacent panels.
Subtask 57-51-37-865-058-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 57-51-37-410-055-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B11 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/ELAC1/NORM/SPLY | 15CE1 | B06 |
| ** ON A/C ALL | |||
| 105VU | FLIGHT CONTROLS/ELAC2/STBY SPLY | 16CE2 | A02 |
| 105VU | FLT CTL/ELAC1/STBY SPLY | 16CE1 | A01 |
| 121VU | FLIGHT CONTROLS/ELAC2/NORM/SPLY | 15CE2 | R20 |
B. Close Access
(1) Remove the access platform(s).
Subtask 57-51-37-860-067-A (1) Remove the access platform(s).
C. Aircraft Maintenance Configuration
(1) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the flap/slat control lever.
Subtask 57-51-37-942-062-A (1) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the flap/slat control lever.
D. Removal of Equipment
(1) Remove the safety barriers.
(2) Remove the WARNING NOTICE(S).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the safety barriers.
(2) Remove the WARNING NOTICE(S).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Lower Trailing Edge Access Panels - Location and Detail