W DOC AIRBUS | AMM A320F

Visual Inspection of the Thrust Reverser Half Door Opening Actuator [CFMB]


TASK 78-36-51-210-041-A
Visual Inspection of the Thrust Reverser Half Door Opening Actuator


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 27-80-00-866-005-A
Retracting the Slats on the Ground
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-36-00-010-040-B
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-B
Closing of the Thrust Reverser Doors
TASK 78-36-51-000-041-A
Removal of the Thrust Reverser Half Door Opening Actuator
TASK 78-36-51-400-041-A
Installation of the Thrust Reverser Half Door Opening Actuator
AIPC 78-36-51-
3. Job Set-up
Subtask 78-36-51-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-36-51-010-052-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Put an ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-36-51-040-051-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 78-36-51-869-052-A ** ON A/C NOT FOR ALL
D. Retract the Wing Slats
CAUTION: RETRACT WING SLATS BEFORE OPENING THRUST REVERSER OR DAMAGE CAN OCCUR.
   (1) Retract the slats (Ref. AMM TASK 27-80-00-866-005) and install a WARNING NOTICE(S).
Subtask 78-36-51-010-053-A ** ON A/C NOT FOR ALL
E. Open the thrust reverser doors to 45 degree position (Ref. AMM TASK 78-36-00-010-040):
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure
Subtask 78-36-51-210-050-A ** ON A/C NOT FOR ALL
A. Do a Visual Inspection of the Thrust Reverser Half Door Opening Actuator and Hydraulic Hose
INSPECT/CHECK
MAXIMUM SERVICEABLE LIMITS
REMARKS
1.Inspect the half door opening actuator for:


A.Damage
No damage permitted
If you find some damage, replace the door opening actuator (Ref. AMM TASK 78-36-51-000-041) and (Ref. AMM TASK 78-36-51-400-041)
B.Crack
No crack permitted
If there is a crack, replace the door opening actuator (Ref. AMM TASK 78-36-51-000-041) and (Ref. AMM TASK 78-36-51-400-041)
C.Hydraulic leakage
The Dynamic rate of 4 drops per 25 actuation cyles is allowed.
The static rate of 4 drops in 8 hours is allowed.
If the leakage comes from the nipple, check the nipple for correct torque (Ref. AMM TASK 78-36-51-400-041).
If the leakage is beyond the permitted limits, replace the door-opening actuator (Ref. AMM TASK 78-36-51-000-041) and (Ref. AMM TASK 78-36-51-400-041)


If the leakage comes from the body of the actuator, replace the door opening actuator (Ref. AMM TASK 78-36-51-000-041) and (Ref. AMM TASK 78-36-51-400-041)
2.Inspect the related hardware of the door opening actuator for:


A.Damage
No damage permitted
If you find some damage, replace the damaged part (Ref. AMM TASK 78-36-51-000-041) and (Ref. AMM TASK 78-36-51-400-041)
3.Inspect rod end pin for correct installation:
Make sure the rod end pin head is on the top of the actuator. Make sure the washer and circlip are on the bottom and tight.
If pin head is on the bottom and washer is on the top, reinstall actuator. If washer and circlip are found missing or loose, replace the actuator. (Ref. AMM TASK 78-36-51-000-041) and (Ref. AMM TASK 78-36-51-400-041)
4.Inspect the hydraulic hose for:


A.Damage
No damage permitted
If you find some damage, replace the hydraulic hose (Ref. AMM TASK 78-36-51-000-041) and (Ref. AMM TASK 78-36-51-400-041)
B.Hydraulic leakage
No hydraulic leakage permitted
If there is leakage, check coupling nuts for correct torque (Ref. AMM TASK 78-36-51-400-041).


If the leakage continues, replace the hydraulic hose (Ref. AMM TASK 78-36-51-000-041) and (Ref. AMM TASK 78-36-51-400-041)
5.Examine the door opening actuator cooling jackets, look for:


A.Blocked Drain
Not allowed
If the drain holes are blocked, remove blockage before next flight.
B.Cracks or Dents
None allowed
If crack or dents are found replace the cooling jacket (Ref. AMM TASK 78-36-51-000-041) (Ref. AMM TASK 78-36-51-400-041).
6.Examine the door opening actuator flexible cooling hoses, look for:


A.Wear or Cuts
Wear or cuts are allowed if they are not fully through the hose
If the wear of cut is fully thru the hose then replace the hose (Ref. AMM TASK 78-36-51-000-041) (Ref. AMM TASK 78-36-51-400-041).
B.Holes
None allowed
If a hole is found then replace the cooling hose (Ref. AMM TASK 78-36-51-000-041) (Ref. AMM TASK 78-36-51-400-041).
7.Examine the clamps and the parts that attach the clamps, look for:


A.Missing clamp or attaching part
None allowed
If a clamp or nut is missing replace it AIPC 78-36-51- (Ref. AMM TASK 78-36-51-400-041).
5. Close-up
Subtask 78-36-51-410-052-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser cowl doors (Ref. AMM TASK 78-36-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
   (3) Remove the access platform(s).
Subtask 78-36-51-440-051-A ** ON A/C NOT FOR ALL
B. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 78-36-51-410-053-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:26:46 UTC