Examine the Thrust Reverser C-Duct Locking Actuator for Hydraulic Fluid Leakage [IAE]
TASK 78-32-43-200-010-A
Examine the Thrust Reverser C-Duct Locking Actuator for Hydraulic Fluid Leakage
1. Reason for the Job
This TASK supplies hydraulic fluid leakage limits for the left and right c-duct locking actuator. Leakage can occur from the forward end cap/jack head interface or rod end seals. A small amount of leakage is acceptable for a limited continued service.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 78-32-43-010-053-A ** ON A/C NOT FOR ALL
Subtask 78-32-43-010-055-A ** ON A/C NOT FOR ALL
Subtask 78-32-43-410-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:28:31 UTC
Examine the Thrust Reverser C-Duct Locking Actuator for Hydraulic Fluid Leakage
1. Reason for the Job
This TASK supplies hydraulic fluid leakage limits for the left and right c-duct locking actuator. Leakage can occur from the forward end cap/jack head interface or rod end seals. A small amount of leakage is acceptable for a limited continued service.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451CL, 452CR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461CL, 462CR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-31-00-710-041-A | Operational Test of the Thrust Reverser System with the CFDS |
| TASK 78-31-00-710-041-A-02 | Operational test of the Thrust Reverser without the CFDS and Engine Running |
| TASK 78-31-00-710-041-A | Operational Test of the Thrust Reverser System with the CFDS |
| TASK 78-31-00-710-041-A-02 | Operational test of the Thrust Reverser without the CFDS and Engine Running |
Subtask 78-32-43-010-053-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 78-32-43-040-052-A ** ON A/C NOT FOR ALL (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
B. Deactivate the Thrust Reverser
Subtask 78-32-43-010-054-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Deactivate the thrust reverser Hydraulic Control Unit (HCU) (Ref. AMM TASK 78-30-00-040-012). C. Remove the translating sleeve actuator access panel.
(1) FOR [1000EM1] (ENGINE-1)
451CL 452CR
(2) FOR [1000EM2] (ENGINE-2)
461CL 462CR.
Subtask 78-32-43-110-050-A ** ON A/C NOT FOR ALL Subtask 78-32-43-440-051-A ** ON A/C NOT FOR ALL 4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451CL 452CR
(2) FOR [1000EM2] (ENGINE-2)
461CL 462CR.
Subtask 78-32-43-010-055-A ** ON A/C NOT FOR ALL
A. Extend and retract the translating sleeve for one minute with the power on (Ref. AMM TASK 78-31-00-710-041)
Subtask 78-32-43-040-053-A ** ON A/C NOT FOR ALL B. Deactivate the Thrust Reverser
Subtask 78-32-43-210-052-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Deactivate the thrust reverser Hydraulic Control Unit (HCU) (Ref. AMM TASK 78-30-00-040-012). C. Check for Leaks using the Following Limits
5. Close-up| | FOR NORMAL OPERATION | FOR DISPATCH TO AVOID DELAY |
|---|---|---|
| Static Seals | None | 2 Drops per 10 minutes |
| Rod seal (system pressurized) | 1 Drop per minute | 30 Drops per minute |
| Rod seal(in operation) | 1 Drop per cycle | 2 Drops per cycle |
Subtask 78-32-43-410-054-A ** ON A/C NOT FOR ALL
A. Install the actuator access panels
(1) FOR [1000EM1] (ENGINE-1)
451CL 452CR
(2) FOR [1000EM2] (ENGINE-2)
461CL 462CR.
Subtask 78-32-43-410-055-A ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451CL 452CR
(2) FOR [1000EM2] (ENGINE-2)
461CL 462CR.
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010).
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 78-32-43-710-053-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010).
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
C. Operational Test
(1) Do an operational test of the thrust reverser system (Ref. AMM TASK 78-31-00-710-041).
(1) Do an operational test of the thrust reverser system (Ref. AMM TASK 78-31-00-710-041).
NOTE: As an alternative procedure, you can do the operational test without the CFDS (Ref. AMM TASK 78-31-00-710-041).
Illustration of the Locking Actuator Access Panel