General Visual Inspection of Thrust Reverser Crossover Beams, Hinges and Latches [IAE]
TASK 78-32-00-210-802-A
General Visual Inspection of Thrust Reverser Crossover Beams, Hinges and Latches
Refer to the MPD TASK: 783201-I8
GENERAL VISUAL INSPECTION OF THRUST REVERSER CROSSOVER BEAMS, HINGES AND LATCHES
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-32-00-941-071-A ** ON A/C NOT FOR ALL
Subtask 78-32-00-210-070-A ** ON A/C NOT FOR ALL
Subtask 78-32-00-410-087-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:28:00 UTC
General Visual Inspection of Thrust Reverser Crossover Beams, Hinges and Latches
ZONE: 400
1. Reason for the JobRefer to the MPD TASK: 783201-I8
GENERAL VISUAL INSPECTION OF THRUST REVERSER CROSSOVER BEAMS, HINGES AND LATCHES
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-31-00-710-041-A | Operational Test of the Thrust Reverser System with the CFDS |
| TASK 78-31-00-710-041-A-02 | Operational test of the Thrust Reverser without the CFDS and Engine Running |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
| SRM 511100 | |
| SRM 512200 | |
Subtask 78-32-00-941-071-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
Subtask 78-32-00-010-088-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 2M (6 FT) in position.
Subtask 78-32-00-040-068-A ** ON A/C NOT FOR ALL (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 2M (6 FT) in position.
C. Deactivate the Thrust Reverser.
Subtask 78-32-00-010-089-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Deactivate the thrust reverser Hydraulic Control Unit (HCU) (Ref. AMM TASK 78-30-00-040-012). D. Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-32-00-210-070-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Do a general visual inspection of the thrust-reverser crossover beams, hinges, latches and hinge fittings on the pylon side.
(a) Corrosion damage:
5. Close-up(1) Do a general visual inspection of the thrust-reverser crossover beams, hinges, latches and hinge fittings on the pylon side.
(a) Corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 512200 for the types, inspection, removal and corrosion protection.
- If you find other damage, refer to the Structural Repair Manual SRM 511100 for the damage classification and corrective action.
Subtask 78-32-00-410-087-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 78-32-00-440-065-A ** ON A/C NOT FOR ALL Subtask 78-32-00-410-088-A ** ON A/C NOT FOR ALL (1) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
C. Close Access
(1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Subtask 78-32-00-710-067-A ** ON A/C NOT FOR ALL (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
D. Operational Test
(1) Do an operational test of the thrust reverser system (Ref. AMM TASK 78-31-00-710-041).
(1) Do an operational test of the thrust reverser system (Ref. AMM TASK 78-31-00-710-041).
NOTE: As an alternative procedure, you can do the operational test without the CFDS (Ref. AMM TASK 78-31-00-710-041).
Forward Crossover Beams and Hinges