Deactivation of the Thrust Reverser with one Blocker Door missing [IAE]
TASK 78-32-00-040-011-A
Deactivation of the Thrust Reverser with one Blocker Door missing
1. Reason for the Job
CDL 78-03
Thrust Reverser Blocker Door
(old CDL reference: 78-3)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-32-00-941-070-A ** ON A/C NOT FOR ALL
Subtask 78-32-00-040-066-A ** ON A/C NOT FOR ALL
Subtask 78-32-00-410-083-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:27:52 UTC
Deactivation of the Thrust Reverser with one Blocker Door missing
1. Reason for the Job
CDL 78-03
Thrust Reverser Blocker Door
(old CDL reference: 78-3)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-040-013-A | Deactivation of the Thrust Reverser System for Flight |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
| TASK 78-32-42-000-010-A | Removal of the Left Thrust Reverser Blocker Door Drag Links |
| TASK 78-32-45-000-010-A | Removal of the Left Thrust Reverser Blocker Doors |
| TASK 78-32-72-000-010-A | Removal of the Right Blocker Door Link Assembly |
| TASK 78-32-75-000-010-A | Removal of the Right Thrust Reverser Blocker Doors |
Subtask 78-32-00-941-070-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-32-00-010-085-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
Subtask 78-32-00-040-065-A ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
C. Deactivate the Thrust Reverser:
Subtask 78-32-00-010-086-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Deactivate the thrust reverser Hydraulic Control Unit (HCU) (Ref. AMM TASK 78-30-00-040-012). D. Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR.
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR.
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 78-32-00-040-066-A ** ON A/C NOT FOR ALL
A. Deactivation of the Thrust Reverser with one blocker door missing.
(1) Remove the blocker door (Ref. AMM TASK 78-32-45-000-010) or (Ref. AMM TASK 78-32-75-000-010).
(2) Remove the blocker door link assembly (Ref. AMM TASK 78-32-42-000-010) or (Ref. AMM TASK 78-32-72-000-010).
5. Close-up(1) Remove the blocker door (Ref. AMM TASK 78-32-45-000-010) or (Ref. AMM TASK 78-32-75-000-010).
(2) Remove the blocker door link assembly (Ref. AMM TASK 78-32-42-000-010) or (Ref. AMM TASK 78-32-72-000-010).
Subtask 78-32-00-410-083-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust reverser half (Ref. AMM TASK 78-32-00-410-010).
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 78-32-00-440-063-A ** ON A/C NOT FOR ALL Subtask 78-32-00-440-064-A ** ON A/C NOT FOR ALL Subtask 78-32-00-410-084-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust reverser half (Ref. AMM TASK 78-32-00-410-010).
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.