W DOC AIRBUS | AMM A320F

Removal of the Thrust Reverser Actuation System (TRAS) Filter Module [PW11]


TASK 78-31-02-000-801-A
Removal of the Thrust Reverser Actuation System (TRAS) Filter Module


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: WEAR APPLICABLE PERSONAL PROTECTIVE EQUIPMENT (PPE) WHEN YOU DO THIS TASK. BEFORE YOU USE PPE, READ, UNDERSTAND AND OBEY ALL INSTRUCTIONS FOR ITS USE. THESE INSTRUCTIONS INCLUDE INSTRUCTIONS FROM THE MANUFACTURER, YOUR EMPLOYER AND GOVERNMENT REGULATIONS. YOU CAN GET INJURED IF YOU DO NOT USE PPE. GET INSTRUCTIONS FROM YOUR EMPLOYER ON WHICH PPE IS NECESSARY.
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES. WORK ON THE HYDRAULIC SYSTEMS CAN BE DANGEROUS.
FIN: 4314KM1 ** ON A/C NOT FOR ALL
FIN: 4314KM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
COVER - PROTECTION
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.PU1-0001)
lint-free cotton cloth
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
471CL
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
482CR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 54-53-11-000-804-A
Removal of the Pylon-to-Wing Access Panels and Doors
TASK 71-00-00-860-833-A
Procedure to Prevent Engine Motoring
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
TASK 29-10-00-864-001-A
Depressurize the Green Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
TASK 29-10-00-864-002-A
Depressurize the Yellow Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
3. Job Set-up
Subtask 78-31-02-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833)
Subtask 78-31-02-864-051-A ** ON A/C NOT FOR ALL
B. Depressurization of the Hydraulic System
   (1) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the applicable system.
     (a) On the HYD/FUEL panel 40VU of the overhead panel
     (b) On the ground service panel of the applicable hydraulic system.
   (2) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
     (a) Depressurize the Green hydraulic system (Ref. AMM TASK 29-10-00-864-001).
     (b) Depressurize the reservoir of the Green hydraulic system (Ref. AMM TASK 29-14-00-614-001).
   (3) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
     (a) Depressurize the Yellow hydraulic system (Ref. AMM TASK 29-10-00-864-002).
     (b) Depressurize the reservoir of the Yellow hydraulic system (Ref. AMM TASK 29-14-00-614-001).
Subtask 78-31-02-040-051-A ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser for Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 78-31-02-010-051-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
   (2) Remove the access panel on the pylon (Ref. AMM TASK 54-53-11-000-804):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
471CL
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
482CR
4. Procedure
Subtask 78-31-02-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the TRAS Filter Module
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING: YOU MUST NOT GET HYDRAULIC FLUID ON YOUR SKIN, IN YOUR EYES OR IN YOUR MOUTH. THE HYDRAULIC FLUID IS POISONOUS AND CAN BE ABSORBED INTO YOUR BODY. IF YOU ACCIDENTALLY GET HYDRAULIC FLUID IN YOUR EYES, MOUTH OR ON YOUR SKIN, FLUSH WITH WATER AND GET MEDICAL AID.
CAUTION: YOU MUST NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT- FREE CLOTH. THE HYDRAULIC FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND SOME PARTS.
   (1) Drain the inlet tube
     (a) Put lint-free cotton cloth (Material No.PU1-0001) below the inlet tube to the filter module (1) to collect hydraulic fluid that possibly can spill.
     (b) Disconnect the inlet tube from the filter module (1).
   (2) Drain the outlet tube
     (a) Put lint-free cotton cloth (Material No.PU1-0001) below the outlet tube to the filter module (1) to collect hydraulic fluid that possibly can spill.
     (b) Disconnect the outlet tube from the filter module (1).
   (3) Remove the TRAS Filter Module
     (a) Remove the four bolts (2), four washers (3) and four nuts (4) that attach the filter module (1) to the filter bracket on the pylon.
     (b) Remove the filter module (1) from the pylon.
   (4) Installation of the protection covers
CAUTION: INSTALL PROTECTION COVERS ON ALL THE OPENINGS IMMEDIATELY TO PREVENT DAMAGE TO THE ENGINE.
     (a) Make sure that you install COVER - PROTECTION as necessary to prevent damage to the engine.
[Rev.10 from 2021] 2026.04.01 03:31:06 UTC