W DOC AIRBUS | AMM A320F

Inspection/Check of the High Pressure Turbine Active Clearance Control Valve (HPTACC) [CFMB]


TASK 75-21-10-200-002-A
Inspection/Check of the High Pressure Turbine Active Clearance Control Valve (HPTACC)


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 451AL, 452AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 70-51-00-230-002-A
Fluorescent-Penetrant Inspection-Portable-Water Washable
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 75-21-10-000-002-A
Removal of the High Pressure Turbine Active Clearance Control (HPTACC) Valve
TASK 75-21-10-400-002-A
Installation of the High Pressure Turbine Active Clearance Control (HPTACC) Valve
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-36-00-010-040-B
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-B
Closing of the Thrust Reverser Doors
3. Job Set-up
Subtask 75-21-10-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 75-21-10-010-055-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowls doors: (Ref. AMM TASK 71-13-00-010-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 75-21-10-040-054-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 75-21-10-010-056-A ** ON A/C NOT FOR ALL
D. Open Thrust reverser doors: (Ref. AMM TASK 78-36-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
4. Procedure
Subtask 75-21-10-210-052-A ** ON A/C NOT FOR ALL
A. Do a visual inspection of the HPT active clearance control (HPTACC) valve as follows:
INSPECT/CHECK
MAXIMUM SERVICEABLE LIMITS
REMARKS
1.Valve housing for:


  • cracks
Not serviceable.
Replace the valve (Ref. AMM TASK 75-21-10-000-002) and (Ref. AMM TASK 75-21-10-400-002).
  • deformation
Not serviceable.
Replace the valve (Ref. AMM TASK 75-21-10-000-002) and (Ref. AMM TASK 75-21-10-400-002).
  • nicks or scratches
Any amount

2.Flanged joints for:


  • loose bolts or nuts
Not serviceable.
TORQUE the bolts (Ref. AMM TASK 75-21-10-400-002).
  • cracks
Not serviceable.
Replace the valve (Ref. AMM TASK 75-21-10-000-002) and (Ref. AMM TASK 75-21-10-400-002)
  • deformed or bent
Not serviceable.
Replace the valve (Ref. AMM TASK 75-21-10-000-002) and (Ref. AMM TASK 75-21-10-400-002).

PRE CFM SB 75-0012

3.Ceramic Insulators for PRE SB 75-0026 and earlier


  • Looseness
Not serviceable
NOTE: POST SB 75-0026 and later do not have ceramic insulators.
Remove the valve (Ref. AMM TASK 75-21-10-400-002)

END OF PRE CFM SB 75-0012



POST CFM SB 75-0012

4.Ceramic Insulators for:


- Not applicable


END OF CFM SB 75-0012

Subtask 75-21-10-230-051-A ** ON A/C NOT FOR ALL
B. If a crack is suspected after visual inspection, do a fluorescent penetrant inspection to make sure of actual or suspected cracks in the valve housing or a flanged joint (Ref. AMM TASK 70-51-00-230-002).
5. Close-up
Subtask 75-21-10-410-054-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser doors: (Ref. AMM TASK 78-36-00-410-040).
     (a) FOR [1000EM2] (ENGINE-2)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 75-21-10-440-053-A ** ON A/C NOT FOR ALL
B. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
   (1) Remove the WARNING NOTICE(S).
Subtask 75-21-10-410-055-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:10:05 UTC