W DOC AIRBUS | AMM A320F

Route Ignition Leads to return to normal configuration [CFMI]


TASK 74-31-00-440-803-A
Route Ignition Leads to return to normal configuration


WARNING: BEFORE YOU START WORK ON THE IGNITION SYSTEM, MAKE SURE THAT THE IGNITION EXCITERS ARE DE-ENERGIZED FOR A MINIMUM OF FIVE MINUTES. ALSO DO NOT TOUCH THE ELECTRICAL CONTACTS. THE IGNITION SYSTEM VOLTAGE IS VERY HIGH, AND THE IGNITION EXCITERS CAN HAVE AN ELECTRICAL CHARGE EVEN WHEN NOT ENERGIZED. IF YOU DO NOT OBEY THESE PRECAUTIONS, INJURY CAN OCCUR.
CAUTION: BE CAREFUL WITH THE IGNITION LEAD TO PREVENT DAMAGE TO THE CONDUIT AND THE INTERNAL WIRES.
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
MMEL 74-31-01A
IGNITION SYSTEM A (FAA ONLY)
left ignition lead on aircraft battery bus.
MMEL743101
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 160 and 140 lbf.in (1.81 and 1.58 m.daN ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 74-00-00-710-040-A
Operational Test of the Ignition System
TASK 74-00-00-710-040-A-01
Operational Test of the Ignition System without CFDS
TASK 78-30-00-081-041-A
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-36-00-010-040-A
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-A
Closing of the Thrust Reverser Doors
3. Job Set-up
Subtask 74-31-00-941-056-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 74-31-00-865-063-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
FOR FIN: 1000EM1 (ENGINE1)
121VUENGINE/IGN/ENG1/SYS B3JH1P41
121VUENGINE/IGN/ENG1/SYS A BAT2JH1P39
FOR FIN: 1000EM2 (ENGINE2)
121VUENGINE/IGN/ENG2/SYS B3JH2P42
121VUENGINE/IGN/ENG2/SYS A BAT2JH2P40
Subtask 74-31-00-010-054-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 74-31-00-040-053-A ** ON A/C NOT FOR ALL
D. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 74-31-00-010-055-A ** ON A/C NOT FOR ALL
E. Open the thrust reverser doors: (Ref. AMM TASK 78-36-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure
Subtask 74-31-00-020-053-A ** ON A/C NOT FOR ALL
A. Disconnection of the Ignition Leads
   (1) Disconnect the ignition leads from the aft side of the ignition exciters on the fan inlet case.
   (2) Remove the ignition leads from the clamps between the ignition exciters and junction box bundle.
   (3) Install the leads in opposite clamps and connect to ignition exciters.
   (4) Make sure the left lead is not under tension at the ignition exciter. Adjust the lead routing to prevent tension.
   (5) TORQUE the ignition lead connectors to between 160 and 140 lbf.in (1.81 and 1.58 m.daN ) T.
Subtask 74-31-00-865-064-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
FOR FIN: 1000EM1 (ENGINE1)
121VUENGINE/IGN/ENG1/SYS B3JH1P41
121VUENGINE/IGN/ENG1/SYS A BAT2JH1P39
FOR FIN: 1000EM2 (ENGINE2)
121VUENGINE/IGN/ENG2/SYS B3JH2P42
121VUENGINE/IGN/ENG2/SYS A BAT2JH2P40
Subtask 74-31-00-710-056-A ** ON A/C NOT FOR ALL
5. Close-up
Subtask 74-31-00-410-054-A ** ON A/C NOT FOR ALL
A. Close access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser doors: (Ref. AMM TASK 78-36-00-410-040)
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 74-31-00-440-056-A ** ON A/C NOT FOR ALL
B. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 74-31-00-410-055-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-040)
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:07:19 UTC