Check of Ignition Fault Warning [CFML]
TASK 74-31-00-040-806-A
Check of Ignition Fault Warning
MMEL 74-07-01A
SELECTED IGNITER INDICATION ON THE ENGINE SD PAGE (FAA ONLY)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 74-31-00-861-054-A Subtask 74-31-00-865-069-A
Subtask 74-31-00-200-053-A
Subtask 74-31-00-860-057-A
[Rev.10 from 2021]
2026.04.01 03:09:01 UTC
Check of Ignition Fault Warning
ZONE: 210
1. Reason for the JobMMEL 74-07-01A
SELECTED IGNITER INDICATION ON THE ENGINE SD PAGE (FAA ONLY)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
Subtask 74-31-00-861-054-A Subtask 74-31-00-865-069-A
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 74-31-00-860-056-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | ENGINE/1 AND 2/IGN/SYS A | 1JH | A03 |
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENGINE 1) | |||
| 121VU | ENGINE/IGN/ENG1/SYS B | 3JH1 | P41 |
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENGINE 2) | |||
| 121VU | ENGINE/IGN/ENG2/SYS B | 3JH2 | P42 |
C. Aircraft Maintenance Configuration
(1) On the maintenance panel 50VU:
(a) Release the ENG / FADEC GND PWR / 1(2) pushbutton switch. The ON legend of this pushbutton switch comes on.
(2) On the ENG panel 115VU, make sure that:
(a) The ENG/MODE/CRANK/NORM/IGN START selector switch is set to NORM.
(b) The ENG/MASTER 1(2) control switch is set to OFF.
(3) On the overhead control and indicating panel 22VU:
(a) Make sure that the ON legend of the ENG/MAN START/1(2) pushbutton switch is off (the pushbutton switch is released out).
(4) On the HYD/FUEL panel 40VU:
(a) Make sure that the OFF legends of all the FUEL/PUMPS pushbutton switches are on (the pushbutton switches are released out).
(5) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
4. Procedure(1) On the maintenance panel 50VU:
(a) Release the ENG / FADEC GND PWR / 1(2) pushbutton switch. The ON legend of this pushbutton switch comes on.
(2) On the ENG panel 115VU, make sure that:
(a) The ENG/MODE/CRANK/NORM/IGN START selector switch is set to NORM.
(b) The ENG/MASTER 1(2) control switch is set to OFF.
(3) On the overhead control and indicating panel 22VU:
(a) Make sure that the ON legend of the ENG/MAN START/1(2) pushbutton switch is off (the pushbutton switch is released out).
(4) On the HYD/FUEL panel 40VU:
(a) Make sure that the OFF legends of all the FUEL/PUMPS pushbutton switches are on (the pushbutton switches are released out).
(5) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
Subtask 74-31-00-200-053-A
A. Check for ignition fault warning
5. Close-up| ACTION | RESULT |
|---|---|
1.On the ENG panel 115VU:
| On the upper ECAM display unit:
|
WARNING:
MAKE SURE THAT THE INLET PRESSURE INDICATION FOR THE STARTER VALVE IS ZERO BEFORE YOU PUSH THE ENG/MAN START/1 (2) PUSHBUTTON SWITCH. 2.On the overhead control and indicating panel 22VU: | |
|
|
3.On the ENG panel 115VU:
| On the upper ECAM display unit, on the ENGINE page:
|
4.On the overhead control and indicating panel 22VU:
| |
5.On the ENG panel 115VU:
| |
6.On the ENG panel 115VU:
NOTE: The Engine Electronic Controller (EEC) stays electrically supplied for 5 minutes after you set:
NOTE: The WARNING messages that appears during this procedure can be cleared by an ON/OFF switching of the ENG/MASTER 1(2) control switch. | |
Subtask 74-31-00-860-057-A
A. Put the aircraft back to its initial configuration.
(1) On the maintenance panel 50VU:
(a) Push the ENG / FADEC GND PWR / 1(2) pushbutton switch. The ON legend goes off.
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) Make an entry in the logbook.
(4) Put the WARNING NOTICE(S) to tell person that igniter indication is selected on the ENGINE SD page (FAA only).
Subtask 74-31-00-865-070-A (1) On the maintenance panel 50VU:
(a) Push the ENG / FADEC GND PWR / 1(2) pushbutton switch. The ON legend goes off.
(2) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
(3) Make an entry in the logbook.
(4) Put the WARNING NOTICE(S) to tell person that igniter indication is selected on the ENGINE SD page (FAA only).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 74-31-00-862-054-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | ENGINE/1 AND 2/IGN/SYS A | 1JH | A03 |
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENGINE 1) | |||
| 121VU | ENGINE/IGN/ENG1/SYS B | 3JH1 | P41 |
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENGINE 2) | |||
| 121VU | ENGINE/IGN/ENG2/SYS B | 3JH2 | P42 |