Procedure after Halon Products Contamination [CFMB]
TASK 72-00-00-200-042-A
Procedure after Halon Products Contamination
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 72-00-00-941-132-A ** ON A/C NOT FOR ALL
Subtask 72-00-00-280-076-A ** ON A/C NOT FOR ALL
Subtask 72-00-00-410-175-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:40:41 UTC
Procedure after Halon Products Contamination
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.CP2442) | engine oil |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-13-79-610-002-A | Check oil level and replenish Check Pop Out Indicator of EMCD (Electrical Master Chip Detector) |
| TASK 12-13-79-610-002-A-01 | Check oil level and replenish (Pressure Filling) |
| TASK 12-13-79-610-003-C | Oil Tank Draining |
| TASK 12-13-79-610-004-C | Draining of the Accessory Drive Section |
| TASK 71-00-00-710-003-B | Engine Automatic Start |
| TASK 71-00-00-710-028-B | Engine Shutdown |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Subtask 72-00-00-941-132-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 72-00-00-010-172-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 72-00-00-040-090-A ** ON A/C NOT FOR ALL Subtask 72-00-00-010-173-A ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
D. Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 72-00-00-280-076-A ** ON A/C NOT FOR ALL
A. Halon Products Contamination
Use of nacelle extinguishing equipment (fire confirmed or not). No maintenance action.
(2) On ground:
(a) Use of nacelle extinguishing equipment only:
open nacelle doors immediately to disperse halon vapors. No further maintenance action is required.
(b) If halon fluids have been sprayed in the engine (in undetermined quantity), do the following steps.
1 If the engine can be restarted within 30 minutes.
5. Close-upCAUTION:
THE ENGINE CONTAINS NUMEROUS TITANIUM PARTS, THEREFORE HALON SUBSTANCES MUST NOT BE USED.
(1) In flight: Use of nacelle extinguishing equipment (fire confirmed or not). No maintenance action.
(2) On ground:
(a) Use of nacelle extinguishing equipment only:
open nacelle doors immediately to disperse halon vapors. No further maintenance action is required.
(b) If halon fluids have been sprayed in the engine (in undetermined quantity), do the following steps.
1 If the engine can be restarted within 30 minutes.
- Perform a ground run at Idle for 10 minutes (Ref. AMM TASK 71-00-00-710-003).
- Drain oil tank (Ref. AMM TASK 12-13-79-610-003).
- Drain accessory gearbox (AGB) (Ref. AMM TASK 12-13-79-610-004).
- Reservice oil tank with new engine oil (Material No.CP2442) (Ref. AMM TASK 12-13-79-610-002).
- Start and motor the engine for 5 minutes (Ref. AMM TASK 71-00-00-710-003).
- Stop motoring for 5 to 10 minutes (Ref. AMM TASK 71-00-00-710-028).
- Re-start and motor engine for 5 minutes (Ref. AMM TASK 71-00-00-710-003).
- Drain oil tank (Ref. AMM TASK 12-13-79-610-003).
- Drain accessory gearbox (AGB) (Ref. AMM TASK 12-13-79-610-004).
- Reservice oil tank with new engine oil (Material No.CP2442) (Ref. AMM TASK 12-13-79-610-002).
- Perform a ground run at idle for 10 minutes within 3 hours (Ref. AMM TASK 71-00-00-710-003).
Subtask 72-00-00-410-175-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 72-00-00-440-090-A ** ON A/C NOT FOR ALL Subtask 72-00-00-410-176-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR