Inspection of the Front Mount Tube [IAE]
TASK 71-21-12-200-014-A
Inspection of the Front Mount Tube
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-21-12-941-055-A ** ON A/C NOT FOR ALL
Subtask 71-21-12-210-055-A ** ON A/C NOT FOR ALL
Subtask 71-21-12-410-066-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:30:21 UTC
Inspection of the Front Mount Tube
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-20-00-700-010-A | Adjustment of the Front Mount Tube |
| TASK 71-21-11-200-801-A | Inspection of the Front Mount Tube Assembly |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
Subtask 71-21-12-941-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 71-21-12-010-065-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(2) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(3) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(4) Put the ACCESS PLATFORM 2M (6 FT) in to position.
Subtask 71-21-12-040-057-A ** ON A/C NOT FOR ALL Subtask 71-21-12-010-066-A ** ON A/C NOT FOR ALL (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(2) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(3) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(4) Put the ACCESS PLATFORM 2M (6 FT) in to position.
D. Open the thrust reverser halves. (Ref. AMM TASK 78-32-00-010-010):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 71-21-12-210-055-A ** ON A/C NOT FOR ALL
A. Examine the front mount tube.
(1) If the front mount tube touches the mount tube stopper assembly without damages, adjust the tube (Ref. AMM TASK 71-20-00-700-010).
(2) If the front mount tube is damaged, do the inspection of the front mount tube assembly (Ref. AMM TASK 71-21-11-200-801).
5. Close-up(1) If the front mount tube touches the mount tube stopper assembly without damages, adjust the tube (Ref. AMM TASK 71-20-00-700-010).
(2) If the front mount tube is damaged, do the inspection of the front mount tube assembly (Ref. AMM TASK 71-21-11-200-801).
Subtask 71-21-12-410-066-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser halves. (Ref. AMM TASK 78-32-00-410-010):
(3) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(4) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 71-21-12-440-055-A ** ON A/C NOT FOR ALL Subtask 71-21-12-410-067-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser halves. (Ref. AMM TASK 78-32-00-410-010):
(3) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(4) FOR [1000EM2] (ENGINE-2)
461AL 462AR