Detailed Inspection of Outer Wing Trailing Edge Flap Actuator Brackets at Flap Tracks 2, 3 and 4
TASK 57-51-00-220-004-A
Detailed Inspection of Outer Wing Trailing Edge Flap Actuator Brackets at Flap Tracks 2, 3 and 4
Refer to the MPD TASK: 575101-01
DETAILED INSPECTION OF OUTER WING, TRAILING EDGE FLAP ACTUATOR BRACKETS AT FLAP TRACKS 2,3 AND 4
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 57-51-00-941-061-A
Subtask 57-51-00-410-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:14:35 UTC
Detailed Inspection of Outer Wing Trailing Edge Flap Actuator Brackets at Flap Tracks 2, 3 and 4
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
CAUTION:
BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
1. Reason for the Job- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
- MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
Refer to the MPD TASK: 575101-01
DETAILED INSPECTION OF OUTER WING, TRAILING EDGE FLAP ACTUATOR BRACKETS AT FLAP TRACKS 2,3 AND 4
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 98D27803500001 | 1 | LOCKING TOOL ZERO POS |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 570 | AFT SECTION OF L WING & TE FIXED STRUCT |
| 670 | AFT SECTION OF R WING & TE FIXED STRUCT |
| 531CB, 532CB, 533CB, 631CB, 632CB, 633CB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 57-55-11-000-001-A | Removal of the Flap Track Fairings Nos. 2, 3 and 4 |
| TASK 57-55-11-000-004-A | Removal of the Flap Track Fairings Nos. 2, 3 and 4 |
| TASK 57-55-11-400-001-A | Installation of the Flap Track Fairings Nos. 2, 3 and 4 |
| TASK 57-55-11-400-004-A | Installation of the Flap Track Fairings Nos. 2, 3 and 4 |
| SRM 575100 | (for corrective action) |
Subtask 57-51-00-941-061-A
A. Safety Precautions
(1) Install the 98D27803500001 LOCKING TOOL ZERO POS on the flap/slat control lever.
(2) Put WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
(3) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 57-51-00-865-058-A (1) Install the 98D27803500001 LOCKING TOOL ZERO POS on the flap/slat control lever.
(2) Put WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
(3) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 57-51-00-010-054-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B02 |
| ** ON A/C ALL | |||
| 121VU | FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 | 8CV | Q21 |
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below zone 530 (630).
(2) Remove the applicable access panels (Ref. AMM TASK 57-55-11-000-001):
Subtask 57-51-00-010-054-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below zone 530 (630).
(2) Remove the applicable access panels (Ref. AMM TASK 57-55-11-000-001):
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below zone 530 (630).
(2) Remove the applicable access panels (Ref. AMM TASK 57-55-11-000-004):
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below zone 530 (630).
(2) Remove the applicable access panels (Ref. AMM TASK 57-55-11-000-004):
CAUTION:
BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
Subtask 57-51-00-110-056-A - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
- MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
A. Preparation for Inspection
(1) Use a Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the flap actuator brackets at tracks 2, 3 and 4.
Subtask 57-51-00-210-068-A (1) Use a Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the flap actuator brackets at tracks 2, 3 and 4.
B. Detailed Inspection of Outer Wing Trailing Edge Flap Actuator Brackets at Flap Tracks 2, 3 and 4
(1) Examine the flap actuator brackets at tracks 2, 3 and 4 for:
5. Close-up(1) Examine the flap actuator brackets at tracks 2, 3 and 4 for:
- corrosion
- damage
- scratches and scores
- correct condition of protective finish.
NOTE: If necessary, refer to the SRM 575100 for the correct repair procedure.
Subtask 57-51-00-410-055-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure the work area is clean and clear of tool(s) and other items.
(2) Install the applicable access panels (Ref. AMM TASK 57-55-11-400-001):
Subtask 57-51-00-410-055-B ** ON A/C NOT FOR ALL (1) Make sure the work area is clean and clear of tool(s) and other items.
(2) Install the applicable access panels (Ref. AMM TASK 57-55-11-400-001):
A. Close Access
(1) Make sure the work area is clean and clear of tool(s) and other items.
(2) Install the applicable access panels (Ref. AMM TASK 57-55-11-400-004):
Subtask 57-51-00-865-072-A (1) Make sure the work area is clean and clear of tool(s) and other items.
(2) Install the applicable access panels (Ref. AMM TASK 57-55-11-400-004):
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 57-51-00-942-055-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B02 |
| ** ON A/C ALL | |||
| 121VU | FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 | 8CV | Q21 |
C. Removal of Equipment
(1) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the flap/slat control lever.
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
(4) Remove the safety barriers.
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the flap/slat control lever.
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
(4) Remove the safety barriers.
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Flap Actuator Brackets