W DOC AIRBUS | AMM A320F

Special Detailed Inspection of Bottom Cover, Stringers 8, 11 and Steel Straps Rib Bays 12-26


TASK 57-21-00-280-807-A
Special Detailed Inspection of Bottom Cover, Stringers 8, 11 and Steel Straps Rib Bays 12-26


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 540
ZONE: 550
ZONE: 640
ZONE: 650
1. Reason for the Job
Refer to the MPD TASK: 572174-01
SPECIAL DETAILED INSPECTION (HFEC AND US) OF BOTTOM COVER, STRINGERS 8, 11 AND STEEL STRAPS RIB BAYS 12-26.
NOTE: The effectivity of this task is "ALL". To know if this task is applicable to your aircraft, refer to the MPD task applicability.
NOTE: Two persons are necessary to do this procedure, one inside the fuel tank and one outside.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
AR
SAFETY BARRIER(S)
No specific
1
SCRAPER - NON METALLIC
No specific
AR
WARNING NOTICE(S)
98D27803500001
1
LOCKING TOOL ZERO POS
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
540
FUEL TANK
550
VENT SURGE TANK
640
FUEL TANK
650
VENT SURGE TANK
540GB, 540HB, 540JB, 540KB, 540LB, 540MB, 540NB, 540PB, 540QB, 540RB, 550AB, 550BB, 550CB, 550DB, 640GB, 640HB, 640JB, 640KB, 640LB, 640MB, 640NB, 640PB, 640QB, 640RB, 650AB, 650BB, 650CB, 650DB
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 28-10-00-910-001-A
Safety Procedures When You Do Work in a Fuel Tank
TASK 57-27-11-000-001-A
Removal of the Access Panel
TASK 57-27-11-000-002-A
Removal of the Access Panel
TASK 57-27-11-400-001-A
Installation of the Access Panel
TASK 57-27-11-400-002-A
Installation of the Access Panel
SRM 511100
SRM 512200
SRM 512300
SRM 512400
NTM 572174
3. Job Set-up
Subtask 57-21-00-941-112-A
A. Safety Precautions
   (1) Obey the safety procedures when you do work in the fuel tank (Ref. AMM TASK 28-10-00-910-001)
   (2) Install the 98D27803500001 LOCKING TOOL ZERO POS on the slats and flaps control lever.
   (3) In the cockpit, on the center pedestal, put the WARNING NOTICE(S) in position to tell persons not to operate the slats and flaps control lever.
   (4) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 57-21-00-650-104-A
DELETED
Subtask 57-21-00-010-104-A
C. Get Access
   (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE below the applicable wing fuel tank, at zones 540(640) and 550(650).
   (2) Remove the applicable access panels (Ref. AMM TASK 57-27-11-000-001) and (Ref. AMM TASK 57-27-11-000-002):
Subtask 57-21-00-110-108-A
D. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If the inspection area is not sufficiently clean, clean it with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
   (3) If sealant or paint is applied on the inspection area:
  • Remove the sealant with the SCRAPER - NON METALLIC.
  • Remove the paint.
4. Procedure
Subtask 57-21-00-110-100-A
DELETED
Subtask 57-21-00-280-059-A
B. Inspection
   (1) Do a special detailed inspection of the steel-straps rib bays 12-26 for damage or discontinuities NTM 572174. Do this inspection on the bottom cover at stringers 8 and 11.
   (2) Refer to the NTM inspection report and do the applicable step:
     (a) Corrosion:
If you find corrosion, refer to the Structural Repair Manual SRM 512200 for the corrosion types, inspection, removal and subsequent corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual SRM 511100 for the damage types, classification and corrective action.
Subtask 57-21-00-910-050-A
C. Sealant or Paint Application
   (1) If you removed the sealant and/or paint from the inspection area, apply sealant SRM 512400 or paint SRM 512300 on the inspection area.
5. Close-up
Subtask 57-21-00-410-096-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the applicable access panels (Ref. AMM TASK 57-27-11-400-001) and (Ref. AMM TASK 57-27-11-400-002):
Subtask 57-21-00-650-105-A
DELETED
Subtask 57-21-00-942-107-A
C. Removal of Equipment
   (1) Remove the SAFETY BARRIERS.
   (2) Remove the access platform(s).
   (3) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the slats and flaps control lever.
   (4) Remove the WARNING NOTICE(S).
   (5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.04.01 02:10:54 UTC