Detailed Inspection of Window Seals
TASK 56-12-00-220-001-A
Detailed Inspection of Window Seals
Refer to the MPD TASK: 561200-01
DETAILED INSPECTION OF WINDOW SEALS
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 56-12-00-010-050-A
Subtask 56-12-00-220-050-A
Subtask 56-12-00-865-051-A
[Rev.10 from 2021]
2026.04.01 02:07:12 UTC
Detailed Inspection of Window Seals
WARNING:
MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE OPENED, SAFETIED AND TAGGED.
ZONE: 210
1. Reason for the JobRefer to the MPD TASK: 561200-01
DETAILED INSPECTION OF WINDOW SEALS
NOTE: This task can decrease the fuel consumption.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 56-12-11-000-003-A | Removal of the Sliding Window Seal |
| TASK 56-12-11-000-003-A-01 | Removal of the Sliding Window Seal |
| TASK 56-12-11-000-004-A | Removal of the Retainer/Gasket Assembly |
| TASK 56-12-11-000-004-A-01 | Removal of the Retainer/Gasket Assembly |
| TASK 56-12-11-010-001-A | Opening of the Cockpit Sliding Windows |
| TASK 56-12-11-300-802-A | Repair of the Damaged Frame in the Seal Area of the Sliding Window |
| TASK 56-12-11-400-003-A | Installation of the Sliding Window Seal |
| TASK 56-12-11-400-003-A-01 | Installation of the Sliding Window Seal |
| TASK 56-12-11-400-004-A | Installation of the Retainer/Gasket Assembly |
| TASK 56-12-11-400-004-A-01 | Installation of the Retainer/Gasket Assembly |
| TASK 56-12-11-410-001-A | Closing of the Cockpit Sliding Windows |
Subtask 56-12-00-010-050-A
A. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at zone 210, in front of the sliding window.
(2) Open the sliding window (Ref. AMM TASK 56-12-11-010-001).
Subtask 56-12-00-865-050-A (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at zone 210, in front of the sliding window.
(2) Open the sliding window (Ref. AMM TASK 56-12-11-010-001).
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/RADAR/1 | 5SQ1 | K13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/RADAR/2 | 5SQ2 | K14 |
| ** ON A/C ALL | |||
| 122VU | ANTI ICE/WINDOWS/R | 4DG2 | W14 |
| 122VU | ANTI ICE/WHC/2 | 5DG2 | W13 |
| 122VU | ANTI ICE/WINDOWS/L | 4DG1 | X14 |
| 122VU | ANTI ICE/WHC/1 | 5DG1 | X13 |
| 123VU | ANTI ICE/L/WHSLD | 1DG1 | AF10 |
| 123VU | ANTI ICE/R/WHSLD | 1DG2 | AF03 |
Subtask 56-12-00-220-050-A
A. Inspection
(1) For the acrylic sliding windows (GKN supplier, P/N NH...) and the glass sliding windows (PPG supplier, P/N NP...):
(b) Make sure that there are no cracks and blisters on the seal.
(2) For the glass sliding windows (SPS supplier, P/N SPS...):
(b) Make sure that there are no cracks and blisters on the seal.
(d) If you find damage, replace the preformed seal (Ref. AMM TASK 56-12-11-000-003) and (Ref. AMM TASK 56-12-11-400-003).
5. Close-up(1) For the acrylic sliding windows (GKN supplier, P/N NH...) and the glass sliding windows (PPG supplier, P/N NP...):
NOTE: The sliding window must be open to do this inspection.
(a) Do a detailed visual inspection of the seal of the sliding window for damage or discontinuities. (b) Make sure that there are no cracks and blisters on the seal.
NOTE: It is permitted to fly with a damaged pressure seal (all types of damage) with no time limit. This is possible only if there is no pressure leak which causes an unsatisfactory noise level for the crew in the cockpit.
(c) If you find damage, replace the retainer/gasket assembly (Ref. AMM TASK 56-12-11-000-004) and (Ref. AMM TASK 56-12-11-400-004). (2) For the glass sliding windows (SPS supplier, P/N SPS...):
NOTE: The sliding window must be open to do this inspection.
(a) Do a detailed visual inspection of the seal of the sliding window for damage or discontinuities. (b) Make sure that there are no cracks and blisters on the seal.
NOTE: It is permitted to fly with a damaged pressure seal (all types of damage) with no time limit. This is possible only if there is no pressure leak which causes an unsatisfactory noise level for the crew in the cockpit.
(c) Examine the frame in the seal area. NOTE: It is not necessary to remove the seal to examine the frame.
1 If you find damage, repair the frame (Ref. AMM TASK 56-12-11-300-802). (d) If you find damage, replace the preformed seal (Ref. AMM TASK 56-12-11-000-003) and (Ref. AMM TASK 56-12-11-400-003).
Subtask 56-12-00-865-051-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 56-12-00-410-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/RADAR/1 | 5SQ1 | K13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/RADAR/2 | 5SQ2 | K14 |
| ** ON A/C ALL | |||
| 122VU | ANTI ICE/WINDOWS/R | 4DG2 | W14 |
| 122VU | ANTI ICE/WHC/2 | 5DG2 | W13 |
| 122VU | ANTI ICE/WINDOWS/L | 4DG1 | X14 |
| 122VU | ANTI ICE/WHC/1 | 5DG1 | X13 |
| 123VU | ANTI ICE/L/WHSLD | 1DG1 | AF10 |
| 123VU | ANTI ICE/R/WHSLD | 1DG2 | AF03 |
B. Close Access
(1) Close the sliding window (Ref. AMM TASK 56-12-11-410-001).
(2) Remove the access platform(s).
(1) Close the sliding window (Ref. AMM TASK 56-12-11-410-001).