W DOC AIRBUS | AMM A320F

Detailed Inspection of the Pylon Aft Fixed Fairing


TASK 54-54-00-200-002-A
Detailed Inspection of the Pylon Aft Fixed Fairing


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 470
ZONE: 480
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
470
ENGINE 1 AFT PYLON
480
ENGINE 2 AFT PYLON
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 54-56-00-000-002-A
Removal of the Lower Fairing
TASK 54-56-00-400-002-A
Installation of the Lower Fairing
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
TASK 78-32-00-410-010-A
Closing of the Thrust Reverser Halves
SRM 545412
SRM 545611
3. Job Set-up
Subtask 54-54-00-941-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC.
Subtask 54-54-00-010-053-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Open the thrust reverser doors (Ref. AMM TASK 78-32-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
   (3) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
     (a) At zone 470 for the left pylon
     (b) At zone 480 for the right pylon.
Subtask 54-54-00-020-061-A ** ON A/C NOT FOR ALL
C. Removal of the Components
   (1) Remove the lower fairing (Ref. AMM TASK 54-56-00-000-002).
Subtask 54-54-00-040-053-A ** ON A/C NOT FOR ALL
D. Aircraft Maintenance Configuration
   (1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-040-012).
Subtask 54-54-00-110-050-A ** ON A/C NOT FOR ALL
E. Cleaning of the Structure
   (1) Clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a lint-free cotton cloth Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
4. Procedure
Subtask 54-54-00-220-063-A ** ON A/C NOT FOR ALL
A. Inspection
F Pylon Aft Fixed Fairing ** ON A/C NOT FOR ALL
   (1) Do a detailed inspection of the lower surface of the lower spar of the pylon aft fixed fairing.
   (2) Make sure that there is no:
     (a) Damages:
  • If you find damages, refer to the Structural Repair Manual SRM 545611 and SRM 545412 for corrective action.
5. Close-up
Subtask 54-54-00-420-060-A ** ON A/C NOT FOR ALL
A. Installation of the Components
   (1) Install the lower fairing (Ref. AMM TASK 54-56-00-400-002).
Subtask 54-54-00-440-053-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-440-012).
Subtask 54-54-00-410-053-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the thrust reverser doors (Ref. AMM TASK 78-32-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
   (2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (3) Make sure that the work area is clean and clear of tools and other items.
   (4) Remove the access platform(s).
   (5) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 02:03:00 UTC