W DOC AIRBUS | AMM A320F

Removal of the Aft Centering Pins at RIB5


TASK 54-51-43-000-802-A
Removal of the Aft Centering Pins at RIB5


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
ZONE: 410
ZONE: 420
FIN: 4020KM1 ** ON A/C NOT FOR ALL
FIN: 4020KM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
NOTE: Two persons are necessary to do this task.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
410
ENG 1 PYLON BOX AND FORWARD FAIRING
420
ENG 2 PYLON BOX AND FORWARD FAIRING
415BL, 415BR, 425BL, 425BR
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR, 451AL, 452AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 26-21-41-000-001-E
Removal of the Engine Fire-Extinguisher Bottle
TASK 54-51-21-000-802-A
Removal of the Pylon Lateral Access-Doors
TASK 71-00-00-860-833-A
Procedure to Prevent Engine Motoring
TASK 71-00-51-000-802-A
Removal of the Power Plant (Bootstrap Method)
TASK 71-00-51-000-802-A-01
Removal of the Power Plant (JacXson Method)
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 71-22-41-000-805-A
Removal of the Aft Mount Assembly
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-36-00-010-802-A
Opening of the Thrust Reverser Cowl-Doors
3. Job Set-up
Subtask 54-51-43-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 54-51-43-040-052-A ** ON A/C NOT FOR ALL
B. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 54-51-43-010-051-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR.
   (2) Open the thrust-reverser cowl doors (Ref. AMM TASK 78-36-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR.
   (3) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
     (a) For the left pylon, in zone 415
     (b) For the right pylon, in zone 425.
   (4) Remove the power plant (Ref. AMM TASK 71-00-51-000-802).
   (5) Remove the aft mount assembly (Ref. AMM TASK 71-22-41-000-805).
   (6) Remove the pylon lateral access-doors (Ref. AMM TASK 54-51-21-000-802):
     (a) For the left pylon: 415BL 415BR
     (b) For the right pylon: 425BL 425BR.
   (7) Remove the engine fire-extinguisher bottle (Ref. AMM TASK 26-21-41-000-001).
4. Procedure
Subtask 54-51-43-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Aft Centering Pins at RIB5
F Aft Centering Pins at RIB5 ** ON A/C NOT FOR ALL
NOTE: Two person are necessary to remove the aft centering pins:
  • one to hold the wrench head
  • another one to hold wrench handle.
   (1) Remove the nuts (1) and the washers (2).
   (2) Discard the nuts (1).
   (3) Remove the aft centering pins (3) and (4).
[Rev.10 from 2021] 2026.04.01 02:01:22 UTC