Removal of Oil Lube Module (131-9(A))
TASK 49-91-45-000-003-A
Removal of Oil Lube Module (131-9(A))
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 49-91-45-860-055-A ** ON A/C NOT FOR ALL
Subtask 49-91-45-020-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:33:36 UTC
Removal of Oil Lube Module (131-9(A))
WARNING:
DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | 1 | CONTAINER 10 L(2 1/2 USGAL) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 98L12003001000 | AR | HARNESS,SAFETY |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 315 | TAIL CONE APU AND ACCESSORY COMPARTMENT |
| 316 | TAIL CONE APU AND ACCESSORY COMPARTMENT |
| 315AL, 316AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 49-32-11-000-003-A | Removal of the Fuel Control Unit (FCU) (131-9(A)) |
| TASK 52-41-00-010-001-A | Open the APU Doors for Access |
Subtask 49-91-45-860-055-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(2) On the overhead panel 25VU, make sure that the APU MASTER SW pushbutton switch is released (the ON legend is off).
(3) On the APU section of overhead panel 25VU, put a WARNING NOTICE(S) to tell persons not to start the APU.
(4) Make sure that the hydraulic systems are depressurized
(Ref. AMM TASK 29-00-00-864-001).
Subtask 49-91-45-865-059-A ** ON A/C NOT FOR ALL (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
(2) On the overhead panel 25VU, make sure that the APU MASTER SW pushbutton switch is released (the ON legend is off).
(3) On the APU section of overhead panel 25VU, put a WARNING NOTICE(S) to tell persons not to start the APU.
(4) Make sure that the hydraulic systems are depressurized
(Ref. AMM TASK 29-00-00-864-001).
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 49-91-45-010-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | APU/APU/CTL | 2KD | L42 |
| 121VU | APU/ECB/SPLY | 1KD | L41 |
C. Get Access
(2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the APU access doors 315AL and 316AR.
(3) Open APU access doors 315AL and 316AR (Ref. AMM TASK 52-41-00-010-001).
(4) Set the light switch 11LJ to the ON position.
4. ProcedureWARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
(1) Put on and attach the HARNESS, SAFETY before you start work in the work area.(2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the APU access doors 315AL and 316AR.
(3) Open APU access doors 315AL and 316AR (Ref. AMM TASK 52-41-00-010-001).
(4) Set the light switch 11LJ to the ON position.
Subtask 49-91-45-020-055-A ** ON A/C NOT FOR ALL
A. Remove the Oil Lube Module
(1) Remove the fuel control unit (Ref. AMM TASK 49-32-11-000-003).
(2) Put the CONTAINER 10 L(2 1/2 USGAL) below the oil lube module (4).
(3) Disconnect the electrical connectors (3).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(5) Loosen the captive bolts (1) and remove the oil lube module (4) from the APU.
(6) Remove and discard the packing (2) from the mounting boss.
(1) Remove the fuel control unit (Ref. AMM TASK 49-32-11-000-003).
(2) Put the CONTAINER 10 L(2 1/2 USGAL) below the oil lube module (4).
(3) Disconnect the electrical connectors (3).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(5) Loosen the captive bolts (1) and remove the oil lube module (4) from the APU.
(6) Remove and discard the packing (2) from the mounting boss.
Oil Lube Module