W DOC AIRBUS | AMM A320F

Removal of the Air Intake Flap (APS 3200)


TASK 49-16-43-000-002-A
Removal of the Air Intake Flap (APS 3200)


ZONE: 313
ZONE: 314
1. Reason for the Job
Self explanatory.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
1
FLASHLIGHT
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
98L12003001000
AR
HARNESS,SAFETY
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
313
TAIL CONE APU AIR INTAKE AREA
314
TAIL CONE APU AIR INTAKE AREA
314AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 49-16-43-000-005-A
Removal of the Catwalk Panel (APS3200)
TASK 52-41-23-010-801-A
Opening of Access Door 314AR
3. Job Set-up
Subtask 49-16-43-860-056-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) On the overhead panel 25VU, make sure that the APU MASTER SW pushbutton switch is released (ON legend is off).
   (3) On the APU section of overhead panel 25VU, put a WARNING NOTICE(S) to tell persons not to start the APU.
   (4) Make sure that the hydraulic systems are depressurized
(Ref. AMM TASK 29-00-00-864-001).
Subtask 49-16-43-865-053-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
Subtask 49-16-43-010-059-A ** ON A/C NOT FOR ALL
C. Get Access
WARNING: BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
   (1) Put on and attach the HARNESS, SAFETY before you start work in the work area.
   (2) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below access door 314AR.
   (3) Open access door 314AR and safety it in the open position.
(Ref. AMM TASK 52-41-23-010-801).
   (4) If necessary, use a FLASHLIGHT.
   (5) Remove the catwalk panel (Ref. AMM TASK 49-16-43-000-005).
4. Procedure
Subtask 49-16-43-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the Air Intake Flap
   (1) Get access from behind of the closed air intake flap:
     (a) Remove and discard the cotter pin (3).
     (b) Remove the castle nut (4), the washer (5), the bolt (6) and disconnect the actuator (1) from the air intake flap (8).
   (2) Put the APU MASTER SW pushbutton switch to the ON position to retract the air-intake flap-actuator. If no electrical power is available, do the subsequent steps.
   (3) With a ratchet spanner, turn the manual override device of the air intake flap-actuator (47 and one quarter turns) and fully open the air intake flap.
   (4) Hold the air intake flap (8) and remove the screws (7) from the hinge assembly (10).
   (5) Remove the air intake flap (8) from the air inlet duct (2).
[Rev.10 from 2021] 2026.04.01 01:27:56 UTC