Removal of the HP-Bleed Override Solenoid


TASK 36-11-58-000-001-A
Removal of the HP-Bleed Override Solenoid


WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
ZONE: 471
ZONE: 481
FIN: 11HA1 ** ON A/C NOT FOR ALL
FIN: 11HA2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
471
PYLON LEADING EDGE
481
PYLON LEADING EDGE
FOR [11HA1] (SOL-HP BLEED OVERRIDE, ENG1)
415AL, 415AR
FOR [11HA2] (SOL-HP BLEED OVERRIDE, ENG2)
425AL, 425AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 49-00-00-860-009-A
APU Shutdown by External Power (131-9(A))
TASK 49-00-00-860-009-A-01
APU Shutdown by Batteries (131-9(A))
3. Job Set-up
Subtask 36-11-58-861-050-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-58-941-050-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) Make sure that the engine 1(2) shutdown occured not less than 5 minutes before you do this procedure.
   (2) On the AIR COND panel 30VU:
  • make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend is on),
  • make sure that the APU BLEED pushbutton switch is released (ON legend is off),
  • put a WARNING NOTICE(S) to tell persons not to operate the pneumatic system.
   (3) On the center pedestal, on the ENG panel 115VU:
  • put a WARNING NOTICE(S) to tell persons not to start the engine 1(2).
   (4) On the HP ground connector:
  • put a WARNING NOTICE(S) to tell persons not to pressurize the pneumatic system.
   (5) On the maintenance panel 50VU:
  • make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off,
  • put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 36-11-58-865-050-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 11HA1 (SOLHP BLEED OVERRIDE, ENG1)
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
FOR FIN: 11HA2 (SOLHP BLEED OVERRIDE, ENG2)
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
Subtask 36-11-58-010-050-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the access doors :
     (a) FOR [11HA1] (SOL-HP BLEED OVERRIDE, ENG1)
415AL 415AR
     (b) FOR [11HA2] (SOL-HP BLEED OVERRIDE, ENG2)
425AL 425AR
   (2) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position below the engine.
4. Procedure
Subtask 36-11-58-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the HP-Bleed Override Solenoid
   (1) If you use the APU to energize the electrical circuits, stop the APU:
   (2) In the cockpit, on the SD bleed page:
     (a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
   (3) Disconnect the electrical connector (3) from the HP-Bleed Override Solenoid (4).
   (4) Disconnect the sense line (7) from the HP-Bleed Override Solenoid (4).
   (5) Remove the screws (2) and the washers (1) that attach the HP-Bleed Override Solenoid (4).
   (6) Remove the HP-Bleed Override Solenoid (4) from the support (6).
   (7) Remove the seal (5) and discard it.
   (8) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (9) Put the PLUG-BLANKING in each disconnected line end.